Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> OWT <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS USING THE FOLLOWING EQUATION <br /> DO NOT SAMPLE WELL FOR P=n e x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS where <br /> P=calculated purge volume(gallons) <br /> n=314 <br /> r=radius of well casing in feet <br /> h=height of water column m feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMITS THE CALCULATED PURGE VOLUME WHILE <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUNDWATER <br /> CALCULATED PURGE VOLUME STABILIZATION INDICATOR PARAMETERS <br /> (pH,CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME <br /> • <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA WELL RECHARGES TO A LEVEL <br /> pH = 0 1 pH units SUFFICIENT FOR SAMPLE <br /> COND =110% COLLECTION WITHIN 24 HOURS <br /> TEMP =� 10 OF OF EVACUATION TO DRYNESS <br /> YES NO YES NO <br /> WELL PURGING CONTINUE PURGING,EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING <br /> STABILITY SAMPLING <br /> FIGURE <br /> EMCON MONITORING WELL PURGING PROTOCOL B-1 <br />