Laserfiche WebLink
r., <br /> Table 6 <br /> Soli Vapor Extraction System Emission Data <br /> ARCO Service Station No.548 <br /> 1612 Hammer Lane,Stockton,California <br /> TPH as Gasoline Benze e <br /> Blower Thermal Effluent Effluent <br /> Oxidizer <br /> Hour Meter Influent Operating Extraction Concen- Emission Destruction Concen- Emission Destruction Is System <br /> Sample Date Reading Pressure Temp Flow Rate tration Rate Efficiency tration Rate Efficiency In Compliance <br /> ID _ _ _Sampled (hours) (in HBO) (°F) (scfm) (ppmv) (lbs/day) (percent) (ppmv) (Ibs/day) (percent) with SJVUAPCD <br /> EFFL 10/20/2003 23482.4 10.5 137 54.0 <2.8 0.05 99% <0.03 0.00 80% Yes <br /> EFFL 11/18/2003 24034.5 8.0 133 42.3 <2.8 0.04 99% <0.03 0.00 60% Yes <br /> EFFL 12/22/2003 24586.5 7.2 120 42.3 <2.8 0.04 99% <0.03 0.00 80% Yes <br /> San Joaquin Valley Unified Air Pollution Control District Permit#N-4124-1-0 Conditions are as follows: <br /> Either the VOC control efficiency shall not be less than 95%,or the total VOC emissions rate shall not exceed 2 pounds in any one day. <br /> The minimum operating temperature for the combustion chamber of the catalytic oxidizer shall be maintained at or above 600 degrees F. <br /> The total VOC emission rate from the soil remediation system served by the catalytic oxidizer shall not exceed 6.6 pounds in any one day. <br /> Notes: <br /> =Not measured or analyzed Ibs =Pounds <br /> <4,9 =Below detection limit ppmv =Parts per million by volume <br /> in H.0 =Inches water column scfm =Standard cubic feet per minute <br /> TPH =Total petroleum hydrocarbons <br /> Please Note: Data starts at 4003 <br /> n <br /> K:1WprocessW5 BP ARCO10054814 OTR 0410&M-4Omr03 1 of 1 <br />