Laserfiche WebLink
Station 548 Technical data: <br /> 10/16/03 <br /> 0900--GB.onsite. SVE operating normal_ Sparge com ressor tripped circuit breaker. Belt <br /> off between motor and compressor. Reset belt. Applied power to compressor. Motor <br /> sparked and smoked. Breaker tripped_ Runtime= 902.8. Collected motor data for <br /> replacement. <br /> SVE—Opened wells 4, 5S, 5D. Closed all remaining wells. 50"H2O vacuum at PD <br /> Blower inlet. System inlet = 46 cfm. Well vacuums: 34 "H2O. <br /> PID Readings: 79 ppm inlet, 0.5 ppm effluent. <br /> Collected samples at 1230. <br /> Readings: <br /> Oxidizer Runtime: 20044.5 <br /> Vacuum Controller: 47.4 " H2O <br /> Catalyst Inlet: 689 F <br /> Catalyst Center: 717 F <br /> Catalyst Outlet: 684 F <br /> Blower Outlet Temp: 164 F <br /> System Flowrate: 47 cfm <br /> Blower inlet vacuum: -50 "H2O <br /> Well manifold temp: 81 F <br /> Well manifold vac: -47 "H2O <br /> Electric Utility: 93778 kWh <br />