My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0002938
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
3500 - Local Oversight Program
>
PR0545250
>
ARCHIVED REPORTS_XR0002938
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 5:40:00 PM
Creation date
1/30/2020 4:17:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0002938
RECORD_ID
PR0545250
PE
3528
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
02
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S E C 0 R <br /> . Ms Victoria McCartney <br /> March 24, 2005 <br /> Page 7 , <br /> Soil Analytical Results <br /> Single detections of MtBE were reported in boring MW-12 at approximately 15 feet bgs <br /> (0 0064 mg/kg) and in boring MW-11 at approximately 25 feet bgs (0 0065 mg/kg) <br /> Petroleum hydrocarbons and other fuel oxygenates were reported below laboratory <br /> reporting limits Soil analytical results are presented in Table 2 The certified laboratory <br /> analytical report and chain of custody documentation are presented in Attachment 5 <br /> Groundwater Analytical Results <br /> GRO were detected in MW-12 at 52 pg/L, but were not detected above laboratory reporting <br /> limits in well MW-11 TBA, MtBE, EtBE, and TAME were detected in both off-site wells at <br /> maximum concentrations of 120 lag/L (MW-12), 2,800 lag/L (MW-12), 0 79 lag/L (MW-11), <br /> and 24 pg/L (MW-12), respectively BTEX, DIPS, 1,2-DCA, and EDB were not detected <br /> above laboratory reporting limits in groundwater from the off-site wells Groundwater y <br /> analytical results are presented In Table 3 The certified laboratory analytical report and <br /> chain-of-custody documentation are presented in Attachment 6 <br /> y <br /> RinsatelPurge Water and Soil Cuttings <br /> Soil cuttings and waste water generated during the installation and development of wells <br /> MWA1 and MWA2 were temporarily stored on-site in nine State of California, Department <br /> of Transportation (DOT)-approved 55-gallon steel drums Five drums containing soil <br /> cuttings and four drums containing waste water were removed from the site by Filter <br /> Recycling Services, Inc (FRS) on February 8, 2005, and transported to their Hayward <br /> facility for temporary storage The soil cuttings and waste water are then hauled to FRS' <br /> facility in Rialto, California for recycling/disposal <br /> CONCLUSION <br /> The results of this off-site assessment indicate the presence of an off-site dissolved <br /> petroleum hydrocarbon plume consisting mainly of MtBE and TBA SECOR will add these <br /> wells to the quarterly monitoring and sampling program during the first quarter 2005 to <br /> evaluate the presence of petroleum hydrocarbons and fuel oxygenates beneath and in the <br /> vicinity of the site <br /> LIMITATIONS <br /> This report has been <br /> p prepared for the exclusive use of ConocoPhillips and BP and its <br /> representatives as it pertains to the property located at 3202 West Hammer Lane, Stockton, <br /> California The evaluation of subsurface conditions at the site for the purpose of this <br /> investigation is inherently limited due to the number of points of investigation There are no <br /> representations, warranties, or guarantees that the results are representative of the entire <br /> 11ConocoPhdlips\Retail Sites1111931Reports111193 Off-Site Well Install 1-05 doc SECOR Intemattonal Incorporated <br />
The URL can be used to link to this page
Your browser does not support the video tag.