Laserfiche WebLink
9 <br /> ATTACHMENT A <br /> FIELD AND LABORATORY PROCEDURES <br /> Sampling Procedures <br />' The sampling procedure for each well consists first of measuring the water level and checking <br /> for the presence of separate-phase hydrocarbons (SPH), using either an electronic indicator <br /> and a clear Teflon® bailer or an oil-water interface probe Wells not containing SPH are then <br /> purged of approximately three casing volumes of water (or to dryness) using a centrifugal <br /> pump, gas displacement pump, or bailer Equipment used for the current sampling event is <br /> noted on the attached field data sheets During purging, temperature, pH, and electrical <br /> conductivity are monitored in order to document that these parameters are stable prior to <br /> collecting samples After purging, water levels are allowed to partially recover Groundwater <br /> samples are collected using a Teflon® bailer, placed into appropriate EPA-approved <br />' containers, labeled, logged onto chain-of-custody documents, and transported on ice to a <br /> California state-certified laboratory <br /> Laboratory Procedures <br /> Groundwater samples collected were analyzed for the presence of total petroleum <br />' hydrocarbons calculated as gasoline using modified EPA Method 8015 Groundwater <br /> samples collected were analyzed for the presence of benzene, toluene, ethylbenzene and <br />' xylenes, using modified EPA Method 8020 The five gasoline oxygenates (MtBE, DIPE, <br /> ETBE, TAME and TBA) were analyzed by EPA Method 8260 <br /> Shaw Environmental&Intrastructum,Inc <br /> SAC 1N\nmcfpl\Projects\Projeds1880\040\la\0107\20021880040_2g02 doe-01\tt 1 <br /> (01070000) <br /> A-1 <br />