My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0081494_SSNL (2)
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRENCH CAMP
>
25
>
2600 - Land Use Program
>
SR0081494_SSNL (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 2:01:03 PM
Creation date
1/31/2020 9:53:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0081494
PE
2602
FACILITY_NAME
FRENCH CAMP TRUCK TERMINAL
STREET_NUMBER
25
Direction
E
STREET_NAME
FRENCH CAMP
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95336
APN
19307014
ENTERED_DATE
12/6/2019 12:00:00 AM
SITE_LOCATION
25 E FRENCH CAMP RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7NLS§ 3.3, SSS§ 5.3, 5.4. Table 1 below summarizes the analyzed soil physical and chemical <br /> eristics from the retrieved soil sample: <br /> TABLE 1 <br /> SOIL PROFILE CHARACTERISTICS AND <br /> ANALYTICAL TEST RESULTS <br /> SAMPLE I.D.DEPTH SOIL TEXTURE SOIL.NITRATE- pH AND <br /> CLASSIFICATION NITROGEN CONTENT CATION EXCHANGE CAPACITY <br /> In meq/100g <br /> 3 FT DEPTH Sandy Clay Loam 4 ppm NO;N 8.6 20.0 meq/1008 <br /> (CL,SC) <br /> 8 FT DEPTH Loamy Sand 12 ppm NO,-N 8.3 7.9 meq/100g <br /> ML,SM <br /> C. PERCOLATION TEST RESULTS <br /> SSS§ 6.2. The aforementioned percolation test borings were completed in the location depicted on <br /> the attached Site Plan to assess the permeability of the disposal area soils. <br /> SSS§ 6.3. After drilling the shallow test boring, the sidewalls were scored with a pry-bar to open <br /> potentially smeared sidewalls. The deep 8 ft boring was not scored due to the soil structure. Two <br /> inches of fine gravel was placed at the bottom and three-inch dia. perforated PVC pipe was inserted <br /> in each test boring. After drilling,the test borings were pre-saturated with 12 inches of water, 24 hrs <br /> prior to the start of testing. Maximum soil saturation conditions were achieved to determine the <br /> saturated permeability of the two different soil structures encountered. <br /> SSS§ 6.4, 6.5. On October 11, 2019,percolation testing commenced at 0730 hrs. No standing <br /> water was observed after the 24-hr soak period in either boring. Consequently, EHD Perc Test <br /> Procedure#2 was conducted whereby testing was done over a four-hour period with readings taken <br /> every 30 minutes. <br /> A summary of the perc test results with corresponding application rates in gallons of effluent <br /> accepted per square foot of soil per day are illustrated in Table 2. The corresponding application rate <br /> was obtained from Page 24 of the OWTS Policy- Water Quality Control Policy for Siting. Design, <br /> Operation, and Maintenance of Onsite Wastewater Treatment Systems. <br /> TABLE 2 <br /> PERCOLATION TEST RESULTS WITH CORRESPONDING SOIL TYPE, <br /> PERCOLATION RATE AND APPLICATION RATE IN GALLONS/FT'/DAY <br /> 36 INCH DEEP PERC TEST BORING 83.3 min/inch / 0.123 gallons/ft'/day <br /> SANDY CLAY LOAM <br /> i <br /> 96 INCH DEEP PERC TEST BORING 4.8 min/inch / 1.200 gallons/W/day <br /> LOAMY SAND <br /> Chesney Consulting <br />
The URL can be used to link to this page
Your browser does not support the video tag.