Laserfiche WebLink
}FIELD PROTOCOL 1 <br /> I � <br />' The static water level and floating product level, if present, in each well that contained water was measured <br /> with an ORS Interphase Probe Model No. 1068018 or Solonist Water Level Indicator;these instruments are <br /> accurate to the nearest 0.01 foot. These groundwater depths were subtracted from wellhead elevations, <br /> including corrections for product thickness,when necessary, for gradient evaluation by multiplying product <br /> thickness (PT) by a correction factor 0.8 and subtracting from the DTW (Adjusted DTW = DTW - [PT x <br /> 0.8]). I <br /> Water samples collected for subjective evaluation were.collected by gently towering approximately half the <br /> length of a new disposable or Teflon® bailer past the air-water interface (if possible) and collecting a <br /> L sample from near the surface of the water in the well. The samples were checked for measurable floating <br /> hydrocarbon product. All Teflon® bailers are triple washed with Alconox® and triple rinsed with distilled <br /> Lwater prior to use. <br /> Before water samples.were collected from the groundwater monitoring wells, the wells were purged until <br /> L <br /> . stabilization of the temperature, pH, and conductivity were obtained. Approximately three well casing <br /> volumes were purged before those.characteristics stabilized.. The quantity of water purged from each well <br /> was calculated as follows: <br /> 1 well casing volume=pr2h(7.48)where: <br /> r=radius of the well casing in feet. <br /> h=column of water in the well in feet <br /> (depth to bottom -depth to water). <br /> 7.48=conversion constant from cubic feet tog allons <br /> Gallons of water purged/gallons in 1 well casing volume=well casing volumes removed. <br /> After purging, each well was allowed to recharge to at least 80% of the initial water level.. Water samples <br />' were collected with a new disposable or Teflon® bailer, and carefully poured into 40-milliliter (m]) glass <br /> L vials, which were filled so as to produce a positive meniscus. Each vial was preserved with hydrochloric <br /> acid, sealed with a cap containing a Teflon® septum, and subsequently examined for air bubbles to avoid <br /> k, headspace, which would allow volatilization to occur, The samples were promptly transported in iced <br /> storage in a thermally insulated ice chest, accompanied by a Chain of Custody Record; to a California- <br /> Certified Laboratory. <br /> L <br /> L <br /> LQuarterly GW Monitoring Report-3rd Qtr 2004 <br /> OATC <br /> Quik Stop No. 132 <br /> Quik Stop Markets, Inc. <br /> ATC Project No.75.82503.3205 <br /> LNovember 23,2004 <br /> r <br />