Laserfiche WebLink
iAccu la bs Inc. Formerly West Laboratory <br /> Davis 1046 Olive Drive, Suite 2, Dais CA 95616 ■ 530-757-0920 ■ Fax 753-6091 <br /> ' Subject 7 Water samples Sample Log 19072 <br /> Project Name ATC October 05, 1998 <br /> Project Number <br /> Case Narrative <br /> ' Sample number E17309 (MW-3) <br /> The 4-Bromofluorobenzene surrogate recovery was low The second run of the same sample confirmed <br /> ' the low recovery, indicating a possible matrix effect <br /> Sample Number E17310 (MW-2) <br /> The 1 1 dilution had TAME exceeding calibration range Due to the high dilution factor necessary to report <br /> MTBE in range, the value for TAME in the 1 100 dilution was below the reporting limit The surrogate <br /> ' value exceeded the limit of 120% on the 1 100 dilution <br /> Sample Number E17315 (MW-5) <br /> The surrogate value exceeded the limit of 120%on the 1 10 dilution <br /> I <br /> `rl� <br /> Stew _ <br /> r- <br /> art dolsky <br /> 1 Tempe/Phoenix o Tucson ■ North Phoenix ■ Davis/Sacramento . Durango a Golden 0 Sparks/Reno <br />