My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0080225 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST RIPON
>
12927
>
2600 - Land Use Program
>
SR0080225 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2020 4:33:54 PM
Creation date
1/31/2020 2:52:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0080225
PE
2602
STREET_NUMBER
12927
Direction
W
STREET_NAME
WEST RIPON
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22817008
ENTERED_DATE
2/20/2019 12:00:00 AM
SITE_LOCATION
12927 W WEST RIPON RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12927 West Ripon Road, Ripon April 12, 2019 <br /> Page 2 SR0080225 <br /> 2. The parcel is located within 500 feet from the City of Ripon and is within the city's Sphere of Influence. <br /> Future connection to municipal sewer service may be required when sewer connection becomes <br /> available. <br /> Based on the review of the Study and the Addendum, and the above noted additional considerations, the use <br /> of a standard OWTS, including the augmentations of sawdust under the filter bed for the for the proposed 3- <br /> bedroom second dwelling, is approved. However, the OWTS shall be installed under a Special Permit to <br /> address the variance from the minimum density requirement of one dwelling unit per two acres, and shall be <br /> subject to the following conditions: <br /> A. A Special OWTS Permit is required. <br /> B. There are no permits or well log of the older existing well currently repurposed for irrigation. The seal <br /> depth and construction of the older well are unknown, and may act as a conduit for shallow nitrate <br /> contamination in groundwater to migrate to deeper zone being used for drinking water; therefore, the <br /> older well shall be destroyed under permit within one year from date of OWTS installation. (SJC Well <br /> Standards, Section 6.1) <br /> C. Annual operating permit is required. Fee for annual operating permit is due at time of OWTS permit <br /> application. <br /> D. To monitor the effectiveness of the alternative treatment system, quarterly sampling of the effluent and <br /> under leach field is required. The first sampling shall be done six (6) months after the OWTS <br /> installation. Sampling results shall be submitted to EHD for review. The EHD may reduce the <br /> sampling frequency after one year of sampling. <br /> E. If the alternative treatment system fails to achieve 50% reduction in total nitrogen when comparing <br /> effluent to under leach field, the following will be required: <br /> a. To monitor the potential for groundwater quality impact, an annual sampling of the onsite water <br /> well by a certified laboratory for Nitrate as Nitrogen is required. The analytical results of the <br /> sampling must be transmitted from the certified laboratory to the EHD by December 31St of <br /> each year (San Joaquin County OWTS Standards, Section 3.7.3). <br /> b. If the nitrate concentration continues to rise based on the above-mentioned annual well <br /> sampling, an NSF-approved supplemental treatment system, that performs additional <br /> wastewater treatment so that there is a 50 percent reduction in total nitrogen when comparing <br /> the influent to the effluent before discharge to the dispersal field, shall be installed under permit. <br /> (Regional Water Quality Control Boards OWTS Policy, Section 10.9.1). Plan shall be submitted <br /> to EHD for approval prior to permit issuance. Otherwise, connect to the city sewer if sewer <br /> service from the City of Ripon is available. <br /> F. At grade access lids to the septic tank shall be locked or otherwise secured at all times. (ibid. 5.6) <br /> G. The OWTS shall have an NSF/ANSI certified filter installed at the septic tank effluent discharge pipe. <br /> (ibid. Section 5.7) <br /> H. The OWTS shall be pumped on a regular basis as needed, or at least once every three years. (ibid. <br /> Section 1.12.2(a)) <br /> I. The filter bed shall be constructed as shallow as feasible, with the maximum total depth not to exceed <br /> 42". (ibid. Section 9.8.2) <br /> If you have any questions please call Jeffrey Wong, Lead Senior Registered Environmental Health Specialist, <br /> at (209) 468-0335. <br /> Micel Kith, REHS <br /> Program Coordinator <br /> Cc: Seth Heatwole, 625 West Boesch Dr., Ripon, CA 95466 <br />