FIELD DOCUMENTS_CASE 1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAZELTON
>
375
>
2900 - Site Mitigation Program
>
PR0540905
>
FIELD DOCUMENTS_CASE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 9:28:55 AM
Creation date
2/3/2020 8:37:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
CASE 1
RECORD_ID
PR0540905
PE
2960
FACILITY_ID
FA0023406
FACILITY_NAME
SIERRA LUMBER MANUFACTURERS
STREET_NUMBER
375
Direction
W
STREET_NAME
HAZELTON
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
147120808
CURRENT_STATUS
01
SITE_LOCATION
375 W HAZELTON AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P- 1�'4 I Pagel ofx <br /> SIERRA LUMBER CASE#l0 WC�� 7 <br /> LTCP Checklist GD GEOTRACKER HOME I MANAGE-----1- EPO 3�gF SLUOL GOUT <br /> SIERRA LUMBER CASE#1(TO607700185)-MAP THIS SITE OPEN-VERIFICATIONMONUORING <br /> n 'ERStGHT AGENCIES <br /> 375 HAZELTON AVE W <br /> ACTNITIES REPORT SAN JOAOUINCOUN ARLIN( ILL-LASEa:i144 <br /> SAN JOA UIN COUNTY <br /> MRALVALLERWQCB( NO -S-CAsI50R:ADRIENNE ELLSAEssEft <br /> SAN JOAOUIN COUNTY PUBLIC WEEPAGE CENTRALVALLBVRWVCB(REGION 55)-LARWSOR.CO <br /> CASEWORKEF:JAMES e4FTON.sUPERWSOR:CORI LONDON <br /> VIEW PRINTABLE CASE SUMMARY FOR THIS SUE <br /> THIS PROJECT WAS_AST MODIFIED BY MARL IN KNOLL ON 63x201310:59:47 AM-I191M <br /> THIS SITE HAS SUBMITTALS.CLICK U09 TO OPEN A NEW WINDOW Wm1 THE SUBMITTAL APPROVAL PAGE FOR THIS SITE. <br /> CLOSURE POLICY THIS VERSION IS IN PROGRESS AS OF 512912013 CHECKUST/NITIATED ONMA2013 <br /> General Criteria-The site satisfies the policy general criteria-CLEARS TION ANSWERS YES <br /> a.Is the unauthorized release located within the service area of a ublic waters stem? r YES r NO <br /> Nameof Water System: CalwBler <br /> b.The unauthorized release consists only of petroleum Ju. r YES r NO <br /> c.The unauthorized('primary')release from the UST system has been stopped. R YES r NO <br /> d.Free product has been removed to the maximum extent practicable Jing, 0 FP Not Encountered r YES r' NO <br /> e.A conceptual site model that assesses the nature,extent,and mobility of the release has been developed intpl, Is YES r NO <br /> I.Secondary source has been removed to the extent practicable UDM. r VES r NO <br /> g.Soil w groundwater has been tested for MTBE and results reported in accordance with Health and Safety Code Section r Not Required r YES r NO <br /> 25296.15. <br /> h.Does a nuisance exist,as defined by Water Code section 13050. r YES r NO <br /> 1.Mecila-Specific Criteria:Groundwater-The contaminant plume that exceeds water quality objectives is stable or decreasing in areal extent,and YES <br /> meets all of the additional characteristics of one of the five classes ofsites listed below.-cc s6c <br /> EXEMPTION-Soil Only Case(Release has no Affected Groundwater-Ilia) r YES r NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? r YES r NO JJ� <br /> 1.1-The contaminant plume that exceeds water quality objectives is<100 feet in length.There is no free product.The nearest existing water supply well or r YES r NO <br /> surface water body is>250 feet from the defined plume boundary. <br /> 2.Media Specific Criteria:Petroleum Vapor Intrusion to Indoor Air-The site is considered low-threat forthe vapordnWsion-to-airpathwayI 'te- NO <br /> Specific conditions saflsfy,items 23,2b,or 2c-CLEAR sECnON ANSWERS Ar'� <br /> EXEMPTION-Active Commercial Petroleum Fueling Facility r YES r NO A-`Jl <br /> Does the site meet any of the Petroleum Vapor Intrusion to Indoor Air specific criteda scenarios? r YES <br /> 2a-Scenario 4(example):Direct Measurement of Soil Gas Concentrations VES <br /> I.Soil Gas Sampling Locations—No Bioattenualion Zone: YES <br /> -Beneath or adjacent to an existing building:Soil gas sample is collected at least 5 feel below the bottom of the building foundation. r YES r NO <br /> -Future construction:The soil gas sample shall be collected from at least 5 feel below the ground surface(bgs). r YES r NO <br /> ii.Soil Gas Sampling Locations—with Bioattenuation Zone:The criteria in Column A in the Soil Gas Criteria table(page 5 of the Policy)apply if the <br /> following requirements for a bioatlenuation zone are satisfied: <br /> -Minimum of 5 feet of soil between the soil vapor measurement and the foundation of an existing or grountl surface of future construction. OYES f? NO <br /> -TPH(TPHg+TPHd)is<1 00 mgBg(measured in at least two depths within the 5-ft zone) 0 YES M NO <br /> Oxygen is z 4%measured at the bottom of the 5-ft zone. Efi YES 0 NO <br /> ADDITIONAL QUESTIONS-Please indicate only those conditions that do not meet the policy criteria: <br /> Soil Gas Samples: <br /> C No Soil Gas Samples r Taken Incorrectly <br /> Exposure Type: <br /> r Residential r Commercial <br /> Free Product: <br /> r In Groundwater r In Soil r Unknown <br /> TPH In the BioaOenuation Zone: <br /> Is a 100 mg/kg r Unknown r Soil samples not taken at two depths within 5 ft.zone(only for Scenario 4 with BioZone) <br /> Bioadenuadon Zone Thickness: <br /> C' <5 Feet(No BioZone) r z 5 Feet and<10 Feet r z 10 Feet and<30 Fest r z 30 Feet r 30ft BioZone Compromised TPH>100mgtkg Or Unknown <br /> 02 Data in Bloattenuafion Zone: <br /> fir No02Data r02<4% r02z4% <br /> Benzene in Groundwater: <br /> r a 100 pgtl and<1,000 Ug/1 r 21,000 pgA r Unknown <br /> Soil Gas Benzene: <br /> r z 85 pglm3 and<280 pg/m3 r z 280 pg/m3 and<85,000 pg/m3 r z 85,000 pg/m3 and<280,000 pg/m3 r z 280,000 pg/m3 r Unknown <br /> Soil Gas EthylBenzene: <br /> r a 1,100 pgtm3 and<3,600 pgtm3 r z 3,600 pg/m3 and<1,100,000 pglm3 r a 1,100,000 pgtm3 and<3,600,000 pg/m3 r z 3,600,000 pgtm3 r Unknown <br /> Soil Gas Naphthalene: <br /> https://geotracker.waterboards.ca.gov/regulators/screens/closure_policy.asp?global_id=TO... 7/15/2013 <br />