Laserfiche WebLink
Tracer Research Corporation <br /> Continuing calibration checks are analyzed to verify the detector response for <br /> ' the target VOCs If the response changes by more than 25 percent, the gas <br /> chromatograph is recalibrated and new response factors are calculated <br /> Field system blanks are analyzed to check for contamination of the sampling <br /> apparatus, e g , probe and sampling syringe A sample is collected using standard <br /> ' soil gas sampling procedures, but without putting the probe into the ground The <br /> results are compared to those obtained from a concurrently sampled ambient air <br /> analysis <br /> ' If the blanks detect compounds of interest at concentrations that indicate <br /> equipment contarmnation or concentrations that exceed normal background levels <br /> ' (ambient air analysis), corrective actions are performed If the problem cannot be <br /> corrected, an out-of-control event is documented and reported <br /> A reagent blank is performed to ensure the solvent used to dilute the stock <br /> standards is not contaminated Analytical instruments are calibrated daily using <br /> fresh working standards made from National Institute of Sciences and Technology <br /> (NIST) traceable standards and reagent blanked solvents <br /> Quantitative precision is assured by replicating analysis of 10 percent of the <br /> samples Replicate analyses are performed by subsampling vapors from the original <br /> syringe and VOA <br /> I <br /> 7.0 RESULTS <br /> ' The analytical results from this soil gas and groundwater investigation are <br /> condensed in Appendix A The data are presented by location and by analyte <br /> concentration When the compound was not detected,the detection lirrut is <br /> ' presented as a "less than" value, e g , <0 1 µg/L <br /> Samples are identified by sample type, sample location, and sampling depth <br /> ' For example, SG-1-12' represents a soil gas sample collected from soil gas location <br /> 1 at a depth of 12 feet bgs Sample WS-4-11' represents a water sample collected <br /> ' from groundwater location 4 at a depth of 11 feet bgs <br /> July 19 1994 Page 9 11402915 <br />