My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE_FILE 2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
15600
>
3500 - Local Oversight Program
>
PR0545273
>
SITE INFORMATION AND CORRESPONDENCE_FILE 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 12:18:49 PM
Creation date
2/3/2020 11:05:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
FileName_PostFix
FILE 2
RECORD_ID
PR0545273
PE
3528
FACILITY_ID
FA0000174
FACILITY_NAME
JOES TRAVEL PLAZA
STREET_NUMBER
15600
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19620079
CURRENT_STATUS
02
SITE_LOCATION
15600 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Robert Trommer Page 3 of 7 <br /> Comments on CUF Site Closure Recommendations for Various Sites March 3, 2010 <br /> Claim No. 3484-2360 East Street,Trac <br /> This site is in the closure process needing only monitoring well destruction. The EHD is awaiting <br /> the permit applications for the well destructions and anticipates site closure in one to three <br /> months. <br /> Claim No. 679 -5814 E. Charter Way, Stockton <br /> This site is in the closure process needing only monitoring well destruction. The EHD <br /> anticipates site closure in one to three months. <br /> Claim No. 7709 -2969 Loomis Road, Stockton <br /> As the EHD commented in May 2009 to the CUF five-year review closure recommendation, <br /> there are several factors that lead the EHD to consider closure of this site to be premature at <br /> this time. Those factors are as follows: <br /> • All eight monitoring wells have groundwater above the wells screened intervals (as much <br /> as twenty feet in MW-1). There appears to be a correlation between depth-to-water and <br /> concentrations detected in groundwater from the monitoring wells - as depth-to- <br /> groundwater increase, diesel concentrations also increase. <br /> • The EHD is concerned about the sudden drop in diesel concentrations reported in <br /> groundwater collected from MW-4, MW-5, and MW-7 in April 2008. The significant <br /> decrease coincides with a change in laboratories. During the October 28, 2008, <br /> sampling event, groundwater samples collected from MW-5 and MW-7 were sent to two <br /> different laboratories, and the results from the two laboratories were significantly <br /> different. The verification laboratory reported diesel at 2,210 micrograms per liter (ug/L) <br /> in MW-5 and 7,480 ug/L in MW-7, while the laboratory that had been detecting markedly <br /> lower concentrations reported diesel at 580 ug/L in MW-5 and 620 ug/L in MW-7. <br /> • Based on the soil contaminant mass for diesel estimated to be approximately 27,000 <br /> gallons (168,000 pounds) at the end of 2005, our department believes it prudent to try to <br /> remediate the diesel contamination prior to closing this site, especially since a light <br /> sheen continues to be reported in monitoring MW-4 and MW-5. <br /> Three dual-phase extraction wells with well screens that intersect the groundwater table were <br /> installed on the site in January 2010, but have not been developed or sampled as of yet. <br /> Considering that the characterization of shallow groundwater has not yet been completed and <br /> that an estimated 168,000 pounds of diesel is believed to be impacting soil and no remediation <br /> has yet been attempted, the EHD believes it would be beneficial to attempt some site <br /> remediation, reduce the contaminant mass and potential toxicity to microorganisms, and <br /> accelerate the return to background conditions. <br /> Claim No. 8509 - 1207 S. Aurora Street, Stockton <br /> This site is in the closure process needing only monitoring well destruction. The EHD anticipates <br /> site closure in one to three months. <br /> Comments on CUF Site Closure Recommendations 0310.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.