Laserfiche WebLink
v •-J <br /> 2. Exposure to chemical contamination -through skin contact with and ingestion <br /> of soil. <br /> Ongoing air monitoring during project tasks will provide data to ensure that vapor <br /> concentrations are within acceptable ranges and will provide adequate selection <br /> criteria for respiratory and dermal protection. A Photo Ionization Detector (PID) shall <br /> be utilized for monitoring with a 1 part per million (ppm) detection limit. <br /> • If PID readings taken in the breathing zone exceed 25 ppm sustainable above <br /> background, a NIOSH approved air-purifying respirator with organic vapor <br /> cartridges must be worn by all site workers within the area where the <br /> sustainable elevated level exists, until the level is reduced. <br /> • If PID readings taken in the breathing zone exceed 750 ppm, Level B protection <br /> will be required. Personnel must leave site immediately and contact FSS or <br /> Health & Safety Manager for further instructions. <br /> • Respirator cartridges will be changed once per day as a minimum. This can be <br /> accomplished at the end of the work day during respirator decontamination. <br /> If odor breakthrough is detected while wearing the respirator or breathing <br /> becomes difficult, change cartridges immediately. <br /> If the entry is done "under air", Supplied Air requirements must be adhered to <br /> as well. <br /> 9.1 Stopping Work <br /> Criteria for stopping work and evacuating personnel from the work zone are <br /> listed below. Once work is stopped due to a reason listed below, operations, <br /> work practices and protective strategies will be re-evaluated and modified, if <br /> necessary, through consultation with the FSS prior to resuming activity. <br /> The detection of combustible gas levels in excess of 10 % (LEL) in air, where <br /> fans or air circulation are unable to reduce the LEL less than 10%. <br /> • "Verified" and sustainable organic vapor levels of >50 ppm via the PID <br /> in the breathing zone for periods exceeding 30 minutes. <br /> 0 The detection of gaseous contaminants that cannot be removed by the <br /> Level C respirator at levels above 50% of the OSHA PEL as measured at <br /> the breathing zone via detector tubes. Example: HzS, HCN, mercury <br /> vapor. EXCEPTION: Carbon monoxide - see below. <br /> Avalon Environmental Consultants 9627-001-6 <br /> Kashmar Singh Joes Truck Plaza <br /> January 9, 2001 15 Lathrop, California <br />