ARCHIVED REPORTS_XR0011444
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
3500 - Local Oversight Program
>
PR0545275
>
ARCHIVED REPORTS_XR0011444
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2020 3:22:44 PM
Creation date
2/3/2020 12:38:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011444
RECORD_ID
PR0545275
PE
3528
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
02
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
---------------- ------ ------- - ------- -- ---------------- - ----- ---- - -- ------------ . 21 <br /> S E C 0 R <br /> continue to operate and evaluate the effectiveness of the OS system during the third <br /> quarter 2005. <br /> WASTE DISPOSAL <br /> The volume of purged groundwater generated during the second quarter 2005, and the <br /> method of disposal are documented in TRC's Quarterly Monitoring Report, April through <br /> June 2005 dated July 1, 2005 (Attachment 1). <br /> RECENT SUBMITTALS 1 CORRESPONDENCE <br /> In accordance with the September 13, 2004 Work Plan for Additional Site Assessment, i <br /> SECOR completed the installation of two of the three off-site wells on May 17, 2005 <br /> (MW-23 and MW-24). Well MW-22 was not installed due to the presence of utilities in ' <br /> the immediate vicinity of the proposed location (private property access road). SECOR <br /> submitted an Addendum to Work Plan for the Installation of Well MW-22 on June 17, <br /> 2005, which included a proposal for installing well MW-22 at the same location using <br /> Geoprobe direct push drilling equipment. Following the receipt of the addendum work <br /> plan, the SJCEHD contacted SECOR and indicated that the proposed well construction <br /> details were not in compliance with the California Department of Water Resources <br /> (DWR) Water Well Standards, which require a minimum of two inches of annular space <br /> between the well casing and the borehole. SECOR submitted a Second Addendum for <br /> the Installation of Well MW-22 on July 15, 2005, which proposed the installation of well <br /> MW-22 using the hollow stem auger drilling method, as originally proposed in the initial <br /> work plan, at an alternative location located on private property (Holiday Inn property). <br /> The second addendum work plan was approved by SJCEHD in correspondence dated <br /> July 20, 2005. <br /> CONCLUSIONS AND RECOMMENDATIONS <br /> SECOR will continue to evaluate dissolved concentrations, and operate and perform <br /> monthly maintenance of the OS system at the site. During the third quarter 2005, <br /> SECOR will complete off-site assessment activities to delineate the extent of dissolved <br /> impacts south to southeast of the site. SECOR will submit the results of off-site <br /> assessment activities in a Site Conceptual Model as requested by the SJCEHD in f <br /> correspondence dated September 28, 2004. f <br /> THIS QUARTER ACTIVITIES (Second Quarter 2005) <br /> 1 <br /> 1. SECOR prepared and submitted the Quarterly Summary Report— First Quarter <br /> 2005 on May 6, 2005. <br /> 2. Groundwater monitoring and sampling activities were performed by TRC on May <br /> 25, 2005 and June 6, 2005. On the June 6, 2005 date, TRC uncovered, and <br /> monitored and sampled well MW-14. Well MW-12 was not found during the May <br /> 25, 2005 sampling event due to tall grass in the area; the well was later found, <br /> monitored, and sampled along with well MW-14 on June 6, 2005. <br /> 3. SECOR continued operation, and performed monthly maintenance of the OS <br /> system. <br /> 4. In accordance with the September 13, 2004 Work Plan for Additional Site <br /> >` Assessment, SECOR completed the installation of two of the three off-site wells <br /> I:1ConocoPhillipslRetail Sites1111951QSR&QRPS 2005/11195 QSR&QRPS 2Q05.doc <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.