Laserfiche WebLink
Recommended 1. Pour pellets slowly from surface to minimize bridging of pellets. Break <br /> Treatment up bridges as they occur. <br /> (Metric Equivalents) 2. Pellets can be tremied into place when necessary. Volume needed can <br /> vary by as much as 10 to 15 percent in a rotary drilled hole. <br /> 3. Calculate and monitor pellet addition amounts to ensure proper hole fill <br /> by measuring the position of the top of the plug after every few pails. <br /> 4. Calculated volume should be applied to borehole. <br /> Volume/Amount of BAROID BENTONITE PELLETS Required For <br /> Grouting and Plugging Applications <br /> Nominal Hole Kilograms of PELLETS needed <br /> Size Volume, Liter/meter to fill 1 meter <br /> (mm) m'/meter 1/4" 3/8" 1/2" <br /> 76 0.005 4.6 7.4 7.3 6.9 <br /> 102 0.008 8.1 13.1 13.0 12.4 <br /> 114 0.010 10.3 16.6 16.4 15.6 <br /> 127 0.013 12.7 20.5 20.3 19.3 <br /> 140 0.015 15.3 24.9 24.5 23.4 <br /> 152 0.018 18.2 29.6 29.2 27.8 <br /> 178 0.025 24.8 40.3 39.7 37.8 <br /> 191 0.029 28.5 46.2 45.6 43.4 <br /> 200 0.031 31.4 51.0 50.2 47.9 <br /> 203 0.032 32.4 52.6 51.9 49.4 <br /> 216 0.037 36.6 59.4 58.5 55.8 <br /> 222 0.039 38.8 62.9 62.0 59.1 <br /> 254 0.051 50.7 82.2 81.0 77.2 <br /> 279 0.061 61.3 99.4 98.0 93.4 <br /> 292 0.067 67.0 108.7 107.1 102.1 <br /> 305 0.073 73.0 118.3 116.7 111.2 <br /> 311 0.076 76.1 123.3 121.6 115.9 <br /> 318 0.079 79.2 128.4 126.6 120.6 <br /> 324 0.082 82.4 133.6 131.7 125.5 <br /> 438 0.151 150.8 244.5 241.1 229.8 <br /> 445 0.155 155.2 251.7 248.1 236.5 <br /> 610 0.292 291.9 473.3 466.7 444.7 <br /> 660 0.343 342.6 555.5 547.7 521.9 <br /> 762 0.456 456.1 739.6 729.2 694.9 <br /> 914 0.657 656.8 1065.0 1050.0 1000.7 <br />