My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
I
>
INDUSTRIAL
>
230
>
2900 - Site Mitigation Program
>
PR0009051
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/5/2020 11:52:16 AM
Creation date
2/5/2020 10:01:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0009051
PE
2960
FACILITY_ID
FA0000649
FACILITY_NAME
FORMER NESTLE USA INC FACILITY
STREET_NUMBER
230
STREET_NAME
INDUSTRIAL
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
25938001
CURRENT_STATUS
01
SITE_LOCATION
230 INDUSTRIAL DR
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U'A L f T Y. 0. S S Lt N.N C E Is E T M t) 0;'S <br /> .. ' . : (:SREf <br /> RQport paRc: B9/U9/2i)US <br /> REPORT COMMENTS <br /> 1) ALI pages of this report are integral parts of the analytical data. Therefore, this report should <br /> be reproduced only in its entirety. <br /> 2) Soil, sediment and sludge sample results are reported an a --dry weight-- basis except when analyzed for <br /> Landfill disposal or incineration parameters. All other solid matrix samples are reported on an "as <br /> received" basis unless noted differently. <br /> 3) Reporting limits are adjusted for sample size used, dilutions and moisture content if applicable. <br /> 4) The test results for the noted analytical mothad(s) meet the requirements of NELAC. Lab Cert. LD# 100201 <br /> 5) According to 40CFR Part 136.3, pH, Chlorine Residual and Dissolved Oxygen analyses are to be performed <br /> immediately after aqueous sample collection. when these parameters are not indicated as field (e.g. <br /> PH Field) they were not analyzed immediately, but as soon as possible on laboratory receipt. <br /> Glossary of flags, qualifiers and abbreviations (any number of which may appear in the report) <br /> Inorganic Qualifiers (G-Column) <br /> U Analyte was not detected at or above the stated Limit. <br /> < Not detected at or above the reporting limit. <br /> i Result is less than the RL, but greater than or equal to the method detection Limit. <br /> B Result is less than the CRI)L/RL, but greater than or equal. to the IDL/MDL. <br /> S Result was determined by the Method of Standard Additions. <br /> F AFCEE: Result is Less than the RL, but greater than or equal to the method detection limit. <br /> Inorganic Flags (Flag Column) <br /> - ICV,CCV,ICB,CCB,ISA,ISB,CRI,CRA,MRL; Instrument related QC exceed the upper or Lower <br /> control limits. <br /> * LCS, LCD, MD. Batch QC exceeds the upper or Lower control limits. <br /> MSA correlation coefficient is less than 0.995. <br /> 4 MS, MSD: The analyte present in the original sample is 4 times greater <br /> than the matrix spike concentration; therefore, control limits are not applicable. <br /> E SO: Serial dilution exceeds the control limits. <br /> N MB, EBI, EB2, EB3: Batch QC is greater than reporting limit or had a <br /> negative instrument reading lower than the absolute value of the reporting limit. <br /> N MS, MSD: Spike recovery exceeds the upper or lower control limits. <br /> W AS(GFAA) Post-digestion spike was outside 85-115% control limits. <br /> organic Qualifiers to - cot") <br /> u AnaLyte was not detected at or above the stated Limit. <br /> NO Compound not detected. <br /> J Result is an estimated value below the reporting limit or a tentatively <br /> identified compound (TIC). <br /> Q Result was qualitatively confirmed, but not quantified. <br /> C Pesticide identification was confirmed by GC/MS. <br /> Y The chromatographic response resembles a typical fuel pattern. <br /> Z The chromatographic response does hot resemble a typical fuel pattern. <br /> E Result exceeded calibration range, secondary dilution required. <br /> F AFCEE:Result is an estimated value below the reporting limit or a tentatively identified compound (TIC) <br /> Organic Flags (Flags Colum) <br /> 8 MB: Batch QC is greater than reporting Limit. <br /> ` LCS, LCD, ELC, ELD, CV, MS, MSD, Surrogate: Batch CC exceeds the upper or lower control limits. <br /> - EB1, Egg, EB3, HLF: Batch QC is greater than reporting Limit <br /> A Concentration exceeds the instrument calibration range <br /> a Concentration is below the method Reporting Limit (RL) <br /> B Compound was found in the blank and sample. <br /> D Surrogate or matrix spike recoveries were not <br /> obtained because the extract was diluted for <br /> analysis; also compounds analyzed at a dilution will be flagged with a D. <br /> H Alternate peak selection upon analytical review <br /> I Indicates the presence of an interfence, recovery is not calculated. <br /> M Manually integrated compound. <br /> P The lower of the two values is reported when the % difference between the results of two GC columns is <br /> Page 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.