Laserfiche WebLink
Case Narrative C <br /> Client: Environmental Cost Management, Inc. TestAmerica Job ID: 720-54486-1 <br /> Project/Site: Nestle-Ripon <br /> Job ID: 720-54486-1 <br /> Laboratory:TestAmerica Pleasanton <br /> Narrative <br /> Job Narrative <br /> 720-54486-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 12/19/2013 2:50 PM;the samples arrived in good condition,properly preserved and,where required,on <br /> ice. The temperature of the cooler at receipt was 3.1°C. <br /> GC/MS VOA <br /> Method(s)524.2:The continuing calibration verification(CCV)for Chloromethane associated with batch 152240 recovered above the <br /> upper control limit. The samples associated with this CCV were non-detects for the affected analytes;therefore,the data have been <br /> reported. <br /> Method(s)524.2:The laboratory control sample(LCS)and/or laboratory control sample duplicate(LCSD)for batch 152240 recovered <br /> outside control limits for the following analytes:Chloromethane. These analytes were biased high in the LCS and were not detected in the <br /> associated samples;therefore,the data have been reported. <br /> No other analytical or quality issues were noted. <br /> TestAmerica Pleasanton <br /> Page 4 of 23 12/30/2013 <br />