Laserfiche WebLink
ENVIRONMENTAL COST MANAGEMENT Operator: a'q <br /> FORMER NESTLE PLANT, RIPON, CA Weather: /Cu <br /> PROCESS LOG 0622 9262 Arrival: Tac% Departure: <br /> DATE: C f 9- Nalco 8357 <br /> INDUSTRIAL AVE. GROUNDWATER TREATMENT PLANT <br /> Status upon arrival: Operating Alarm Condition: None <br /> Status upon depart: Operating Reason: N/A <br /> EXTRACTION SYSTEM <br /> Location Water Meter(Gallons) Time Pressure Flow GPM) ON/OFF TDS <br /> EU-3 8 ) it,; 0C, I1 >S3 ON �o " <br /> EU-418 Z0 0 0 Z,;: e 5 ON <br /> EI-1 8 +1 123749850 N/A N/A Puffi-P removed OFF N/A <br /> EW-18 32810100 0 0 OFF N/A <br /> NP N/A N/A OFF N/A <br /> REMEDIATION SYSTEM 2X10000+1X5000#GAC units in series <br /> INFPress EFF Temp C N/A Pumping to Industrial Sewer. TDS <br /> MIDPress EFF Cond. (us/cm) N/A ISamples: E*NoEne INF = N/A <br /> EFFPress EFF pH N/A KWH: MID= N/A <br /> NPPress EFF ORP (mV) N/A Drums: EFF = N/A <br /> STOCKTON AVE. GROUNDWATER TREATMENT PLANT <br /> Status upon arrival: Operating Alarm Condition: None <br /> Status upon depart: Operating Reason: N/A <br /> EXTRACTION SYSTEM IFLOW RATES (GPM) <br /> Location Water Meter(Gallons)I Time I Pressure Panel I Timed I ON/OFF Hours <br /> E-2(8)+1 1 CIC- (�& /Zr;Z, 75 < - N/A <br /> E-6{8 +4 x7051; CZ) i7✓ 1 5c, I 1XI 1 130 1 N/A <br /> NP{8)+5 Pr( 3 �} y. ,Z, -N/A N/A <br /> REMEDIATION SYSTEM <br /> Gallons of 8357 0 PID INF (ppmv) -I.2 Z EFF Temp C N/A <br /> Feed rate, Gal/da oak- PID EFF (ppmv) 0-0f,7 EFF Cond. (us/cm) N/A <br /> Full Chem drums . PID Ambient(ppmv) 0-r,,) EFF pH N/A <br /> Empty Chem drums PID 100 ppmv calgas EFF ORP (mV) N/A <br /> CatOX INLET Temp. -7o5- Gas pressure (psi) Carbon press (psi) N/A <br /> CatOX OUTLET Temp. v Reg. press (in H2O) X_3 AS INF press(psi) <br /> Heat X OUTLET Temp. -2, Burner press (in H2O) 10 NP Boost inlet(psi) N/A <br /> AS INF Vac (" H2O) .3' 1 Blower dis temp(F) (`3 Sump press (psi) N/A <br /> AS EFF Vac(" H2O) 412 I Blower flow(CFM) 30:3 E-2 DTW(ft) 37 <br /> Blower press (" H2O) „ I Comb blower OK? OK E-6 DTW(ft) 12,X, <br /> dB meter at property line to south Main fan filter Vac ("H2O) --v <br /> dB meter at property line to west j Comb Blower filter Vac("H2O) 0� <br /> kWh: Z AS level panel/tube Bag filter I Samples collected? No <br /> kW: .c Flame color lu No r Grease? / <br /> Drums 0 CFP stroke/speed Eclipse actuator setting (EVABU) N/A <br /> COMMENTS: Gas Meter(Cu Ft){5)+1 2- <br /> TDS <br /> TDS ASINF m) N/A <br /> TDS ASEFF (ppm) N/A <br /> [TDS CARBEFF (ppm) N/A <br /> Each visit TDS E2 C TDS E6 <br />