Laserfiche WebLink
J & L Market, Diesel Tank, (Facility 11863), STI-SPOO1 , Febritary 2020 <br /> 4 . 4 Serviceability <br /> 4 . 4 . 1 Tank Repair/ Recommendations <br /> All repair work must be authorized by a Certified Inspector or an Engineer experienced in <br /> storage tank design , before conmiencement of the work by a repair organization . A <br /> Certified Inspector must designate inspection hold points required during the repair or <br /> alteration sequence and minimum documentation to be submitted upon job completion . <br /> The Certified Inspector may give prior general authorization for limited or routine repairs <br /> as long as a Certified Inspector is sure that the repairs will not require hydrostatic testing <br /> or do not require an engineering evaluation . <br /> All proposed design , work execution , materials , welding procedures , examination , and <br /> testing methods must be approved by a Certified Inspector or by an Engineer experienced <br /> in storage tank design . A Certified Inspector or an Engineer experienced in storage tank <br /> design shall approve all specified repair and alteration work at the designated hold points <br /> and after repairs and alterations have been completed in accordance with the <br /> requirements of API Standard 653 . <br /> Rcconuncndations to bring the tank into compliance with AM Standard 653 , along with <br /> additional recommendations , to bring the tank and other components into compliance <br /> with other Codes and Standards , have been identified in this report . Completion of these <br /> items is recommended to ensure successfiâ–º 1 long- term service . All recommendations and <br /> repairs are at the discretion of the tank owner to re- categorize and/or determine if repairs <br /> are warranted and/or desired . <br /> 4 .4. 2 Structural Integrity <br /> The Diesel Tank is in compliance with the requirements of STT Standard SP001 for <br /> structural integrity . Within the next 5 years , complete an external inspection of the tank . <br /> The next formal external inspection should be accomplished by a certified STT- SP001 <br /> inspector prior to February 2025 in accordance with STI Standard SP001 . <br /> i <br /> 4 . 4 . 3 Routine Inspection <br /> Perform routine periodic visual inspections by owner/operator personnel knowledgeable <br /> of the storage facility operations , the tank , and the characteristics of the product stored ; <br /> conduct in accordance with STI Standard SPOOL <br /> F <br /> Note: STI SP001 inspection standard onli , requires Periodic AST Inspection (P) and a Formal E.rternal <br /> Irrspectiorr by a Certilied Inspector (E) Ja ' Category 1 tank behaleen 5, 000 to 30, 000 gallons. A C.(rtegor)P 1 <br /> tank is an Elevated AST with Spill Control and with Continnous Release Detection Method (CRDiYI) . <br /> 9 <br />