Laserfiche WebLink
CURTIS & TOMPKINS SEQUENCE SUMMARY FOR 414353189 ' <br /> Instrument : MSVOA02 Begun : 09/02/14 06 :29 ' <br /> Method : EPA 8260B SOP Version : TVH_8260B_rvl <br /> # File Type Sample ID IMatrix Batch Analyzed IDF Stds Used ' <br /> 001 bi201 IX IH 09/02/14 06:29 11.0 1 <br /> 002 jbi202 ix IB 09/02/14 07:04 11.0 1 <br /> 003 bi203 TUN BFB 09/02/14 07:53 1.0 2 <br /> 004 bi204 ccv 15PPB 09/02/14 08:21 1.0 3 4 5 6 1 <br /> 005 bi205 BS QC755853 Water 214977 09/02/14 09:08 1.0 7 8 9 10 1 <br /> 006 bi206 BSD QC755854 Water 214977 09/02/14 09:43 1.0 7 8 9 10 1 <br /> 007 b1207 X CCV 09/02/14 10:19 1.0 ll 1 <br /> IB 09/0 ' <br /> 006 bi208 X 2/14 10:54 <br /> 009 bi209 BLANK QC755855 Water 214977 09/02/14 11:30 1.0 1 <br /> 010 bi210 SAMPLE 260200-001 Water 214977 09/02/14 12:05 1.0 1 ' <br /> 011 bi2ll SAMPLE 260200-002 Water 214977 09/02/14 12:41 1.0 1 <br /> 012 bi212 SAMPLE 260200-003 Water 214977 09/02/14 13:17 1.0 1 <br /> 013 bi213 SAMPLE 260143-010 Water 214977 09/02/14 13:53 1.0 1 <br /> 014 bi214 SAMPLE 260143-001 Water 214977 09/02/14 14:29 5.0 1 <br /> 015 bi215 SAMPLE 260143-009 Water 214977 0914 15:05 1.0 1 <br /> 016 bi216 SAMPLE 260305-009 Water 214977 09/02/14 15:42 2.0 1 <br /> 017 bi217 SAMPLE 260305-010 Water 214977 09/02/14 1618 1.0 1 ' <br /> 018 bi218 SAMPLE 260305-011 Water 214977 09/02/14 16:55 1.0 1 <br /> 019 bi219 SAMPLE 260305-012 Water 214977 09/02/14 17:31 1.0 1 <br /> 020 bi220 SAMPLE 260305-013 Water 214977 09/02/14 18:07 1.0 1 <br /> 021 bi221SAMPLE 260305-014 Water 214977 09/02/14 18:44 1.0 1 ' <br /> 022 bi222 SAMPLE 260305-015 Water 214977 09/02/14 19:20 1.0 1 <br /> 023 bi223 SAMPLE 260305-016 Water 214977 09/02/14 19:56 1.0 1 <br /> 024 bi224 X IH «t <br /> 09/02/14 20:32 1.0 1 1 <br /> 025 bi225 X IB 109/02/14 21:08 1.0 1 <br /> 026 bi226 X IB 09/02/14 21:44 1.0 1 <br /> 027 bi227 X IB 09/02/14 22:20 1.0 1 <br /> 028 bi228 SAMPLE 260186-002 Water 214977 09/02/14 22:56 1.0 1 <br /> spk «t <br /> MCT 09/03/14 : Matrix spikes were not performed for this analysis in batch <br /> 214977 due to insufficient sample amount. <br /> MCT 09/03/14 : I verified that the Vials loaded on the instrument matched the ' <br /> sequence data entry, for runs 1 through 28 . <br /> Analyst : MCT Date: 09/03/14 Reviewer: LW Date: 09/03/14 ' <br /> Standards used4 1=S25458 2.S24915 3=S23923 4-S25335 5=S25373 6=S24979 7.825464 8=S25398 9=525528 10.524693 11=S25399 <br /> Flags used: <et=out of clack spk=5& spike rule <br /> Page 1 of 1 <br /> 55 of 242 ' <br />