My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
1525
>
2900 - Site Mitigation Program
>
PR0526000
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2026 10:47:28 AM
Creation date
2/6/2020 8:49:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0526000
PE
2965 - RWQCB LEAD AGENCY WASTE DISCHARGE SITE
FACILITY_ID
FA0017598
FACILITY_NAME
LANGE TWINS WINE ESTATE
STREET_NUMBER
1525
Direction
E
STREET_NAME
JAHANT
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
00315008
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
1525 E JAHANT RD ACAMPO 95220
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NVIPage 7 Page 8 <br /> EN VI I March 24,2020 R March 24,2020 <br /> ASSESSMENT, PC Project Number 2020-03-011 ASSESSMENT, PC Project Number 2020-03-011 <br /> General Sampling Techniques —Discard gloves,into garbage bag. Garbage bag is non-hazardous waste and may be <br /> discarded in Class 3 landfill. <br /> The general sampling technique with disposable bailer is as follows: —Decon Pump and piping. <br /> —Complete notes and secure well. <br /> —Wear protective gloves. <br /> —Open the well casing and allow the well to equalize with atmospheric pressure for 10 Record Keeping During Sampling - <br /> minutes. <br /> —Take a water level reading using a decontaminated well sounder. All water samples and QA/QC samples will be collected in accordance with U.S.Environmental <br /> —Purge dome(3)wetted casing volumes with a disposable bailer Three(3)wetted casing <br /> volumes in a 2-inch diameter well with 15 feet of wined casing is about 2.5 Protection Agency(EPA)methodology, including the strict use of Chain-of-Custody forms,EPA <br /> gallons. procedures,and properly labeled containers. <br /> —Follow well purging procedure,complete form attached to this report for pH,electrical <br /> conductivity,temperature,and TDS. <br /> —Discard the purge water according to Section 5.0 of this SAP. Each sample container will be labeled using the following alphanumeric protocol: <br /> —Prepare the appropriate laboratory sample containers with labels and record date,time, <br /> —Record weather,water odor,water turbidity,water depth,and any other noteworthy <br /> observations. —EA(to indicate Envuo Assessment,PC.) <br /> —Fill the laboratory sample container with water from the bailer obtained from the well. —Indicate Monitoring well with number(i.e MW I,MW2) <br /> —Label and place samples on ice in ice chest —Six-digit date and time that the water sample was obtained. <br /> —Discard gloves,bailer,and fabric string into garbage bag. These items are non- <br /> hazardous waste and may be discarded in Class 3 landfill. As an example,if the water sample is obtained from MW-1 on January 15,2020,the individual <br /> —Complete notes and secure well. container will be labeled EA MWl 01/15/2011:59am <br /> The general sampling technique with submergible pump is as follows: The samples will be immediately labeled and placed into ice chests with ice for=sporta- <br /> -Wear protective gloves. tion to the FGL Environmental,located at 2500 Stagecoach Rd,Stockton,CA 95215. <br /> —Open the well casing and allow the well to equalize with atmospheric pressure for 10 <br /> minutes. QA/QC <br /> —Take a water level reading using a decontaminated well sounder. <br /> —Purge three(3)wetted casing volumes with a disposable bailer. Three(3)wetted casing <br /> volumes in a 2-inch diameter well with 15 feet of wetted cuing is about 2.5 QA/QC procedures will be used to minimize the potential for contamination of ground <br /> gallons. <br /> —Follow well purging procedure,complete form attached to this report for pH,electrical water samples taken from the monitoring wells. The QA/QC procedures include the use of dis- <br /> conductivity,and TDS. posable bailers,decontamination of the sampling pumps before sampling (if needed), changing <br /> —Discard the purge water according to Section 5.0 of this SAP. <br /> —Prepare the laboratory sample containers with labels and record due,time, latex protective gloves after each sampling event,and recording sample information on chain£- <br /> -Record weather,water odor,water turbidity,water depth,and any other noteworthy custody forms before leaving the field <br /> observations. <br /> —£ill the appropriate laboratory sample container with water from the vessel containing <br /> water from the pumped well. Analytical Laboratory QA/QC procedures will be typical ofthose used to meet all state and <br /> —Label and place samples on ice in ice chest <br /> federal mandates. QA/QC measures in the laboratory setting may include duplicate, spike,and <br /> standard reference sample analysis. <br /> 6NVIROAS5655L4M,PC GNVatQM1ElJTN, 6IJOPPERPHI GEOLWY ENVIROASSn&S .PC In V cNA¢Nra Wonams1axo-GEOLOGY <br /> CORP:POWIXI 4.a0NNERa FERRY.mum PHON2(84q'1CIriI1 PAx(WM6D- 93 C0RP:POB0x1B4.B0M IrERRYm83805 MiONE- & ,142-7311 FAx(M6U.S493 <br />
The URL can be used to link to this page
Your browser does not support the video tag.