Laserfiche WebLink
Don K . Mukai <br /> MECHANICAL ENGINEER <br /> 1841 Paloma St. Pasadena, CA 91104 <br /> 323-888 -4136 <br /> June 1. 2010 Rev. 10.24.11 <br /> Mrs. Paola Recendez <br /> S. Bravo Systems, inc. <br /> 2929 Vail Ave. <br /> Commerce, CA 90040 <br /> Re: Specification approved by a state registered professional engineer <br /> CCR Title 23,Division 3, Chapter 16,Article 3. Section 2631(d) <br /> This letter is for an engnieering specification review and approval of a secondary containment <br /> system component which is not an integral part of primary containment for an underground <br /> fuel tank storage system in California. The authority for this approval comes from the <br /> California Code of Regulations (CCR) Title 23, Division 3, Chapter 16, Article 3, Section <br /> 2631(d). <br /> I have examined and reviewed the following specifications on the Bravo F-Series fiberglass split <br /> retrofit"Retrofit-S" and"Retrofit-SD-AB" fittings: <br /> 1) UL Certifications Directory MH26018 for Vipel F-764 and F-774 resins <br /> 2) AOC Vipel Product Selection Guide & Corrosion Resistance Guide <br /> 3) Bravo datasheets F-Series-SW-IOA. F-Series-DW IOA,F-Series-BLR-I IA, <br /> F-Series-D-BLR-S-IIB, F-Series-Retrofit-S-1 I B and F-Series-Retrofit-SD-A B-I IA <br /> 4) Bravo Installation Manuals ii-F-SERIES-TS-IIA.ii-F-SERIES-TS-D-I IA. <br /> ii-F-SERIES-SS-09B, ii-F-SERIES-TS-ADJ-iNSERfI; ii-F-SERIES-IX-SS-IIA, <br /> ii-F-SERIES-I X-SS-D-I IA, ii-F-SERIES-LCX-09B, ii-F-SERI ES-LCX-D-09B. <br /> ii-FS-RETROFIT S-I OC, ii-FS-RETROFIT-SD-AB-1 OA, ii-SANDKIT 11 B <br /> 5) Bravo Systems Third Party document 3RP-F-Series and 3RP-FS-F I X-D-BLR-S <br /> 6) Bravo Systems UL Approval document CUL-FSeries <br /> 7) Bravo material compatibility letters Surn ps_AlternativeFuel s_RI and <br /> Fittings_A IternativeFuels_R 1 <br /> 8) Smith Bulletin D4025. D4010 and 132102 <br /> 9) Ameron PSX-20 Adhesive Kit- Bondstrand Product Data FP698B <br /> 10) Bravo ADHESIVE-EPDXY-KIT and ADHESIVE-RETROFIT-EPDXY-.KIT <br /> This system provides a bonded retrofit solution to replace from the inside of a single wall fiberglass <br /> containment sump or from both sides of a double wall fiberglass containment sump, a suspect or <br /> failing flexible penetration fitting.This product maintains the integrity of a single walled containment <br /> sump or both the primary and secondary wall of a double wall containment sump including the <br /> integrity of it's existing interstice by permanently bonding the sump wall to the fiberglass pipe or <br /> conduit at each entry point <br /> Continued on Page 2... <br /> 3RP-FS-RETROFIT-S PAGE 1 of 2 <br />