My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:35:59 PM
Creation date
2/6/2020 8:58:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
574
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY RECE, <br /> VED <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 SEP 192014 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si_qov.orcj/ehd <br /> Fikilli <br /> CONTINUATION FORM Wr O INSPECT N R PO T61w <br /> Facility Address: 99 Shelf 7730 Moreland St, Stockton, CA 95212 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> 6-25-14 and 8-2$13 designated operator monthly inspection reports and failed to document that they <br /> were responded to appropriately. The missing alarms include: 6-11-14 L20 Disp. 516 annular fuel alarm <br /> and 8-1-13 Q3 diesel PLLD shutdown alarm. The designated operator failed to document responses to <br /> the 11-26-13 Q3 PLLD shutdown alarm, 12-20-13 Disp. 7/8 annular fuel alarm, 3-24-14 Q1 87 PLLD <br /> shutdown and gross line failure alarms, 11-2-13 03 diesel PLLD shutdown alarm, and 10-23-13 Q2 91 <br /> PLLD shutdown and gross line failure alarms. During the monthly inspection, the designated operator <br /> shall review the alarm history for the previous month, check that each alarm was documented and <br /> responded to appropriately, and attach a copy of the alarm history with documentation taken in response <br /> to any alarms to the monthly report. Ensure that designated operators performing monthly inspections <br /> at this facility are including all of the required information on the reports_ <br /> 3013. The 87 turbine sump sensor was resting on a hose which prevented the sensor from touching the <br /> bottom of the sump and not located to detect a leak at the earliest opportunity. Monitoring equipment <br /> shall be maintained to be able to detect a leak at the earliest possible opportunity. During the inspection, <br /> the technician repositioned the sensor to the lowest park of the sump to detect a leak at the earliest <br /> opportunity. The hose was moved aside <br /> 404. The vent sump lid is not liquid and vapor tight. A sinal; amount of liquid was found in the fill sumps <br /> of the 87, 91, and diesel USTs. Secondary containment shall be constructed to prevent any water <br /> intrusion into the system by precipitation, infiltration, or surface runoff. Immediately remove this liquid: j <br /> make a hazardous waste determination per Title 22 hazardous waste regulations, and manage <br /> accordingly. Immediately contact a properly licensed, trained, and certified contractor to address the <br /> water intrusion into the UST fill sumps and make the vent sump liquid and vapor tight under permit and <br /> inspection of the EHD. <br /> 999, HSG 25404(e)(4) Electronic submittal requirement on the California Electronic Reporting System <br /> (CERS) has not been met. Facility shall submit electronic information for hazardous materials <br /> management system, including Hazardous Waste aria UST on the CERS website which can be found at <br /> http.,//cers,calepa.gov/, Immediately comply with the CERS electronic submittal requirement per this <br /> section. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation corrected, including supporting documentation by 9-25-14. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTEDbATES WILL BE BILLED AT THE CURRENT HOURLY RATE. q�J <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. I� f <br /> Title: <br /> EHD Inspector: Received By: <br /> Aris Veloso (209) 468-3453 'i3 I <br /> EHD 23-02-003 Rev 04119112 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.