Laserfiche WebLink
P <br /> ,r <br /> FLAG GLOSSARY <br /> ' A This sample does not have a typical gasoline pattern <br /> B1 This sample does not have a typical diesel pattern <br /> B Analyte found in the associated blank as well as the sample <br /> C The sample contains a lighter hydrocarbon than gasoline <br /> ' CN See case narrative <br /> CS Outside control limits or unusual matrix, see case narrative <br /> D The sample extends to a heavier hydrocarbon range than gasoline <br /> d Results on a dry weight basis <br /> ' DIL Result was calculated from dilution <br /> E The sample extends to a lighter hydrocarbon range than diesel <br /> F The sample extends to a heavier hydrocarbon range than diesel <br /> G The positive result for gasoline is due to single component comtamination <br /> I The oil pattern for this sample is not typical <br /> S The result for this compound is an estimated concentration <br /> L The LOS recovery exceeded control limits See the LCS page of this report <br /> ' LM The LCS recovery exeeded control limits, the MS/MSD were in control validating the batch <br /> M MS and/or MSD percent recovery exceeds control limits <br /> MD Unable to calculate MS/MSD recovery due to high amount of analyte greater than 4 times spike level <br /> MR The MS/MSD RPD is greater than method critera The sample was re-extracted and re-analyzed with similar results indica <br /> a non-homogeneous sample <br /> MM The Matrix Spike exceeded control limits LCS was in control validating the batch <br /> MI Outside control limits due to matrix interference <br /> N Manual integration performed on sample for quantification <br /> N/A Not Applicable <br /> NC Not calcuable <br /> NO Not Analyzed <br /> P A post digestion spike was analyzed, and recoveries were within control limits <br /> Q Detection limits elevated due to sample matrix <br /> Q1 Detection limits elevated due to high levels of non-target compounds Sample(s) run at a dilution <br /> R The duplicate APD was greater than 204 The sample was re-extracted and re-analyzed with similar results This <br /> ' indicates a matrix interference in the sample likely a non-homogeneity of the sample <br /> RD RPD not applicable for results less than five times the reporting limit <br /> RP MS/MSD RPD is greater than 204 <br /> SR Surrogate recovery outside control limits See the surrogate page of the report <br /> ' SD Unable to quantitate surrogate due to sample dilution <br /> SC Sample not provided to laboratory in proper sampling container <br /> V volatile analysis was requested, sample container received with headspace <br /> ' X1 The duplicate RPD was greater than 204 Due to insufficient sample, re-analysis was not possible <br /> X Sample was analyzed outside recommended holding times <br /> Y The result for this parameter was greater than the TCLP regulatory limit <br /> Z The pattern seen for the parameter being analyzed is not typical <br />