Laserfiche WebLink
Site History <br /> Boyett Petroleum(419 S.Main St.,Manteca) <br /> Page 9 of 9 <br /> described in Condor's Additional Groundwater Investigation, Monitor Well Destruction and Installation, <br /> and Interim Remediation Pump Test Report, dated January 30, 2004, <br /> On November 26, 2003, a Condor representative was on site to measure water levels and collect <br /> groundwater samples for MTBE laboratory analysis from monitor wells MW-2, MW-3, MW-4R, MW-6 <br /> through MW-11, and EW-1. Monitor well MW-6 was dry, and MW-2 and MW-7 contained an <br /> insufficient water column for sampling. Due to an error by the field technician, MW-8 was not measured <br /> or sampled during the November 2003 monitoring event. Laboratory analytical results indicated that <br /> MTBE was detected in the groundwater samples collected from MW-4R, MW-9, MW-10, MW-11, and . <br /> EW-1. The laboratory analytical results indicated a slight increase in the concentration of MTBE detected <br /> in the groundwater sample collected from MW-9 relative to the previous sampling event conducted in <br /> October 2003. Depth to water measurements indicated that the average groundwater elevation was 12.44 <br /> feet on November 26, 2003. The extremely low groundwater levels in the monitor wells prompted <br /> concerns regarding the reliability of water level measurements; the water level in MW-2 and MW-7 may <br /> have been residual groundwater ponded in the cap at the base of the well casing. An estimated <br /> groundwater gradient of 0.0315 ft/ft towards the southwest was calculated using water level data from <br /> monitor wells MW-3, MW-4R, and MW-10. <br /> On December 31, 2003, a Condor representative was on site to measure water levels and collect <br /> groundwater samples from monitor wells MW-2, MW-3, MW-4R, MW-6 through MW-11, and EW-1. <br /> Laboratory analytical results indicated that MTBE was detected in the groundwater samples collected <br /> from MW-4R, MW-7, MW-9, MW-10, MW-11, and EW-1. TAME was detected in the groundwater <br /> samples collected from MW-7, MW-10, and MW-11. The concentration of MTBE in the groundwater <br /> • samples collected from MW-4R and MW-10 increased relative to the previous sampling event conducted <br /> on November 26, 2003. The concentration of MTBE in the groundwater samples collected from MW-9, <br /> MW-11, and EW-1 decreased relative to the previous sampling event. Groundwater elevations increased <br /> by 1.70 feet relative to the previous monthly monitoring event (November 2003). Static water level <br /> measurements generally indicated a groundwater flow direction to the north. An estimated groundwater <br /> gradient of 0.0057 ft/ft towards the north was calculated using water level data from monitor wells MW- <br /> 2, MW-6, and MW-8. <br /> P 17l1l1l5 rri1T7F1 Rmivt+M-t-oa'17F1 4 An-tt W- PI.-R.CRC Ro+.nrt\RPnnrtslllTAR11 f1f1dM-m'tt M-t-Cita TJictn Anr <br /> - <br />