L <br /> SC&D Boyett Petroleum <br /> 419 South Main Street October 27, 1999 <br /> Manteca, California Page: S <br /> The samples were pumped from a stainless steel bladder pump and carefully <br /> poured from a Teflon bailer into clean glass vials with Teflon-lined screw caps <br /> and half gallon plastic containers provided by the laboratory. Care was taken to <br /> ensure that no air space existed in the vials by inverting to check for bubbles <br /> and re-sampling if necessary. The samples were analyzed within 14 days <br /> according to their EPA methods. Water samples collected for analysis were <br /> analyzed by EPA method 5330/LUFT for total Petroleum Hydrocarbons as <br /> Gasoline, and EPA method 602 for BTX&E and method 8260 for oxygenates <br /> including MTBE. The minimum detection limits used for each analyte will be <br /> 0.5 µg11 for BTEX, and 0.5 mg/l for gasoline and diesel. Analyses are to be <br /> conducted by the State-certified laboratory GeoAnalytical Laboratories, Inc., in <br /> Modesto, California. <br /> 4.0 Analytical Results <br /> 4.1 Soil Analytical Results <br /> The soil sample analysis indicated no detectable levels of Petroleum Hydrocarbons <br /> as Gasoline or BTXE in the eleven (11) soil samples collected from the <br /> borings/wells. The soil sample analysis indicated MTBE contamination is present <br /> ' in MW-1, MW-3, and M4. Samples MW-1@20' and MW-1@30' contain MTBE <br /> contamination at concentrations of 150 ug/Kg and 65 ug/Kg, respectively. The <br /> sample MW-3@18' contains 200 ug/Kg of MTBE. Samples MW-4@10', MW- <br /> 4@15', and MW-4@20' contain MTBE contamination at concentrations of 22 <br /> ug/Kg, 40 ug/Kg, and 45 ug/Kg, respectively. Table 1 provides a tabular summary <br /> of the soil analytical data. The soil sample laboratory results, Chain of Custody <br /> Reports, and QA/QC reports can be found in Appendix B. <br /> 4.2 Groundwater Analytical Results <br /> The groundwater sample analysis indicated that gasoline oxygenate contamination <br /> exists in the groundwater underlying this site. MTBE contamination is present in <br /> MW-1 at a concentration of 2,700 ug/L, MW-3 at a concentration of 5,700 ug/L, <br /> and in MW4 at a concentration of 140 ug/L. Tertiary-Butanol is present in MW-1 <br /> at a level of 98 ug/L. TAME is present in MW-1 and MW-3 at levels of 7.7 ug/L <br /> and 16 uglL, respectively. No other contaminant is present in the groundwater at <br /> significant.levels. Table 2 of this report provides a tabular summary of the <br /> .� groundwater analytical data. The groundwater laboratory results, Chain of <br /> Custody and QA/QC Reports can be found in Appendix C. <br />