My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2005 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:31:40 PM
Creation date
2/10/2020 11:37:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2012
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form: Ack—,idum for Vacuum[Pressure Interstitial Sen. <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form, which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer: VEEDER ROOT Model: TLS 350 System Type: ❑ Pressure; ® Vacuum <br /> Sensor ID <br /> Component(s) Monitored by this Sensor: 87 LINE <br /> 51Sensor Functionality Test Result: ® Pass; E] Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: VAPOR - <br /> S2Sensor Functionality Test Result: ® Pass; ElFail Interstitial Communication Test Result: ® Pass; ❑ Fail <br /> Component(s) Monitored by this Sensor: 91 LINE - <br /> S3 - <br /> Sensor Functionality Test Result: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass; Fail <br /> <br /> Component(s) <br /> Component(s)Monitored by this Sensor: 87 91 VENTS <br /> S4 <br /> Sensor Functionality Test Result: ® Pass; ❑ Fail Interstitial Communication Test Result: ® Pass; E] Fail <br /> Component(s)Monitored by this Sensor: DIESEL LINE -- <br /> S5 ❑ Fail <br /> Sensor Functionality Test Result: ❑ Pass; ® Fail Interstitial Communication Test Result: ® Pass; <br /> Component(s)Monitored by this Sensor: DIESEL VENT - <br /> S6 - - <br /> Sensor Functionality Test Result: ® Pass; El Fail Interstitial Communication Test Result: ® Pass; F-ai.l <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: - <br /> Sensor Functionality Test Result: ❑ Pass; E] Tail Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br /> How was interstitial communication verified? ® Visual Inspection; ❑ Other(Describe in Sec. J, below) <br /> ❑ Leak Introduced at Far End of Interstitial Space; Gauge; -Was vacuum/pressure restored to operating levels in all interstitial spaces? ® Yes ❑No(If no, describe in Sec. J, be/otir) <br /> J. Comments: S5 VAC SENSOR WORKED, BUT FLOAT SWITCH DID NOT _ <br /> Ott YYlC., ----- <br /> Page 4 of 4 <br /> 1 sensors sensor successfully <br /> been demoristr demonstrated to be cormmunileak <br /> at ng throughout tlieenterstice�al space at the furthest point from the <br /> LIN-036A-1/1 <br /> www.unidocs.org Re..01/26/06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.