Laserfiche WebLink
Home >> Ust >% Leak Prevention >1, Lg113 = Vendors <br /> UST Programs - LG 113 <br /> Issue Date:September 1,2004 <br /> Veeder-Root <br /> Secondary Containment Leak Detection (SCLD) <br /> TLS-350/ProMax/EMC Console with Vacuum Sensors 857280-100, 200, 30x, or Assembly 332175-001 <br /> PRESSURE/VACUUM INTERSTITIAL MONITOR <br /> Certification Certified as equivalent to European leak detection standard EN-13160-2 Part 2, as a Class I leak <br /> detection system. <br /> Operating System uses vacuum generated by the turbine pump to continuously maintain a partial vacuum <br /> Principle within the interstitial space of double-walled tanks, double-walled piping, and double-walled <br /> containment sumps. <br /> System is designed to activate a visual and acoustic alarm, and optional turbine pump <br /> shutdown before stored product can escape to the environment. <br /> System is capable of detecting breaches in both the inner and outer walls of double-walled <br /> tanks, double-walled piping, and double-walled containment sumps. <br /> Alarm System alarms when a liquid or air leak occurs which causes the interstitial vacuum to decrease <br /> Condition (pressure to increase) and the system is unable to maintain minimum vacuum. System will also <br /> alarm if liquid is detected in the interstitial space, or if the vacuum level in the interstitial space <br /> decreases at a rate exceeding 85±15 liters/hour. <br /> Applicability Underground double-walled tank, connected double-walled piping, and other connected <br /> interstitial spaces storing gasoline, gasohol, diesel, heating oil #2, kerosene, aviation fuel, <br /> motor oil, water. <br /> Manufacturer's Alarm will activate when interstitial vacuum decreases to 1.7 psi vacuum (3.5"Hg). <br /> Specifications Default maximum vacuum level (pump-off pressure) is 8 psi vacuum (16.3" Hg), but can be set <br /> as low as <br /> 4 psi (8.2" Hg) if the monitored system requires that a lower level of vacuum be maintained. <br /> The interstitial space shall be rated for the operating vacuum of the leak detector, regardless of <br /> temperature and groundwater level fluctuations. <br /> Volume of monitored interstitial space must not exceed 8 m3 for tanks and 10 m3 for piping. <br /> When monitoring double-walled tanks, a fuel appropriate liquid sensor must be located at <br /> lowest point of interstitial space. <br /> Calibration Functional and operational safety tests should be performed in accordance with manufacturer's <br /> instructions.. <br /> Comments Interstitial space is tested continuously. <br /> System is connected to the interstitial space by a single vacuum line. <br /> Vacuum is generated by the turbine pump, and is measured and controlled by a vacuum <br /> sensor. <br />