My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2005 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:31:40 PM
Creation date
2/10/2020 11:37:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2012
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> SofAvare Version Installed: 32 L'� , 02-- <br /> Co lete the following checklist: <br /> Yes ❑ No* Is the audible alarm operational? <br /> Yes ❑ No* Is the visual alarm operat-�;al? <br /> es ❑ No* Were all sensors visually inspected, functionally tested,and confirmed operational? <br /> Ld Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so Ethat Eother equipmen1will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ I)io* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> N/A operational? <br /> Ul"Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak, fails to opera e, or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) Sump/Trench Sensors; Lff Dispenser Coptainment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? &Yes; ❑No. <br /> ❑ Yes LJ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> idN/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill oint(s)and operating ro erl ? If- at what ercent of tank capacity does the alarm trigger? % <br /> ❑ Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors,probes, or other equipment replaced <br /> and list the manufacturer name and model for all replacement arts in Section E, below. <br /> ❑ <br /> Ll <br /> No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) LJ <br /> Product; ❑ Water. If yes,describe causes in Section E,below. <br /> ''es ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> Yes I ❑ No* Is all monitoring equipment oerational Per manufacturer's specifications? <br /> * Ips Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.