My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2005 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:31:40 PM
Creation date
2/10/2020 11:37:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2012
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o?Q"tN 'Q SAN JOAQUIN COUNTY <br /> a: + ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, CA 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.segov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> Facility Address: Service Request#: <br /> �59CO6-301 35 <br /> Onsite Service Technician's Name: ICC Service Technician/Installer Exp.Date: Manufacturer Training: <br /> 7 1 z �3 �— 7 — /3 <br /> r <br /> SERVICE SERVICE A:—Q!;4 <br /> Leak detector <br /> EI mechanical Model: Spill bucket El minimum 5 gallon <br /> El ❑ electronic Serial: ❑ El hour hydrostatic E] Incon TS-STS <br /> ❑ line test programmed <br /> ❑ Caldwell System El Other <br /> Leak detector <br /> El mechanical Model: Spill bucket ❑ minimum 5 gallon <br /> El ❑ electronic Serial: ❑ El hour hydrostatic ❑ Incon TS-STS <br /> ❑ line test programmed <br /> ❑ Caldwell System El Other <br /> r3 7!1 he- sensor <br /> El positive shutdown Model:VK -33�/?-�-�> Primary piping testing at: <br /> ❑ psi <br /> ❑ fail safe Serial#: <br /> . -RIA minutes <br /> sensor Secondary containment testing for: <br /> ❑ ❑ positive shutdown Model: UDC(s) Piping <br /> ❑ fail safe Serial#: Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑ fail safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) -ja Other: see below <br /> L( This UST facility is APPROVED to operate ❑ This UST facility is NOT APPROVED to operate <br /> /vii AGuv\ r <br /> c III, <br /> -7_ _1 , <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY f IME AT D'S CUR ENT HOUR Y,RATE. <br /> EHD Ins r:Al Receiv Title: <br /> l"' {C <br /> EHD 23- �tlVUST SERVICE REQUEST INSPECTION REPORT <br /> Rev 10/06/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.