My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2005 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 3:31:40 PM
Creation date
2/10/2020 11:37:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2012
RECORD_ID
PR0231819
PE
2351
FACILITY_ID
FA0003732
FACILITY_NAME
99 SHELL*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
01
SITE_LOCATION
7700 MORELAND ST
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Secondary Containment <br /> Vacuum Sensing System <br /> Maximize protection with a vacuum <br /> monitored secondary containment <br /> system. <br /> A Secondary Containment Vacuum Features and Benefits Fadlita[esperiodic opetabiliry[esdng <br /> Sensing System for use with Veeder- Satisfy Requirements Leverage Existing Veeder-Root Systems <br /> Root's ATG Systems. The Secondary • Certified to meet California's requitement for Uses STP as the vacuum source and works with <br /> Containment Vacuum Sensing (SCVS) secondary space monitoring for tanks and litres Red jacket and FE STPS <br /> as required by AB 2481 Installs in the STP sump and connects to the <br /> System is designed to detect leaks in double- . Satisfies the requirements for Class I Leak <br /> mg <br /> walled tanks and piping systems while Detection as defined by the European console viare wining co safe t with <br /> Standard IN 13160-2 Able to shale wiring conduit with other <br /> helping to contain a release of product while Veeder-Root intrinsic ally safe(IS)probes and <br /> • 3rd Party,National Work Group and LG113 <br /> under vacuum.The system consists of: listed sensors including sump or line leak sensors <br /> • Intetfams to the Smart Sensor Interface with <br /> • Vacuum Sensors,connected to tank, Reduce Exposure to Risk Embedded Pressure Module <br /> Alarms when vacuum cannot be maintained Provides for positive shut down of pressurized <br /> sump or piping interstices lines when required <br /> • A Submersible Turbine Pump(STP), or when replenish tate exceeds 85 liters per hour Simple installation,on,no need to mess with brine <br /> The system alarms when liquid is detected in <br /> to provide a source of vacuum the secondary space <br /> • A Stuart Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> TLS-350R/EMC w/BIR' <br /> Root's TLS-350 Monitoring System via `" TLS-350 Plus/EMC Enhanced* <br /> intrinsically safe wiring to provide system Sensor Dimensions: TLS-350/EMC' <br /> status,replenish rate,alarm,and diagnostic 5"high x 5"wide 2"deep Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Root P/N Description <br /> of models: 330020-467 _ 4 Vacuum Sensor Kit'for steel tank <br /> 330020-468,-469,-470,-471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> 330020-486 4 Vacuum Sensor Kit'for no tank <br /> • For monitoring double-walled piping 33002o-472 3 Vacuum Sensor Kit'for steel tank <br /> and sum interstices 330020-473,474,475,476 3 Vacuum Sensor KV for fiberglass tanks(4',6',8',10') <br /> P 330020485 3 Vacuum Sensor IW for no tank <br /> • For monitoring double-walled steel tank 3300213-479 2 Vacuum Sensor Kit'for steel tank <br /> interstices(see back page) 330020-461,-462,-483,-484 2 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> • For double-walled fiberglass tanks 330020480 2 Vacuum Sensor tct•for no tank <br /> $ 330020.495 1 Vacuum Sensor KC for no tank <br /> 857280-100 Vacuum Sensor for piping 8 sumps <br /> These kits differ in the number of vacuum 857260-200 Vacuum Sensor for steel tanks <br /> 857280-301;302.-303,-304 Vacuum Sensor for fiberglass tnnl a rn•a•o•,n•. <br /> sensors and the configuration of associated 330020-448 Mounting Kit <br /> liquid sensors.An inline kit mounted liquid )332217-001 Relief Valve Assembly <br /> sensor is used for Vacuum Sensors 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channel)" <br /> monitoring piping and sumps. An external Accessories Part Description QuantNy/Length Part Number <br /> 1/4"NPT Barbed Fittings 3 330020-487 <br /> liquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank)is provided 1/4"NPT Barbed Fittings 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3—Way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Nis Include mounting bracket,6'of vacuum hose.relief valve assembly V required)and the appropriate number of liquid sensors, <br /> 3-way ball valves, barbed fittings and hose damps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> ^The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module,8 channel Smart <br /> Sensor Modules(p/n 329356-004)can be used for Vacuum Sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> e> VEEDER-ROOT <br /> '111111111.0-. <br />
The URL can be used to link to this page
Your browser does not support the video tag.