My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BIRD
>
36314
>
2900 - Site Mitigation Program
>
PR0541398
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2023 1:19:01 PM
Creation date
2/10/2020 2:15:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0541398
PE
2965
FACILITY_ID
FA0011223
FACILITY_NAME
Teichert Vernalis Plant
STREET_NUMBER
36314
Direction
S
STREET_NAME
BIRD
STREET_TYPE
RD
City
TRACY
Zip
95304
CURRENT_STATUS
02
SITE_LOCATION
36314 S BIRD RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 2, 2008 Lab ID : STK0834357 <br /> Luhdorff& Scalmanini Consulting Customer : 3-12023 <br /> Quality Control-Inorganic <br /> Constituent Method Date/ID Type Units Cone. QC Data DQO Note <br /> Wet Chem <br /> Fluoride 300.0 05/02/2008:204745 CCB ppm 0.000 0.1 <br /> CCV ppm 2.500 99.8% 90-110 <br /> CCB ppm 0.000 0.1 <br /> CCV ppm 2.500 108% 90-110 <br /> H%droxide 2320B 05/10/2008:204578 Dup m I 0.0 10 <br /> V1 BAS 5540C 05/02/2008:204320 MS mg/L 1.000 1000 90-110 <br /> MSD mg/L 1.000 100% 90-110 <br /> MSRPD m 1.000 0.0 <0.1 <br /> 5540C 05/02/2008:204701 CCB mg/L 0.000 0.1 <br /> CCV m 1.000 100% 99-101 <br /> �in:uc 300.0 05/02/2008:204323 LCS mg/L 20.00 91.4% 90-110 <br /> MS mg/L 400.0 95.3% 88-124 <br /> MSD mg/L 400.0 104% 88-124 <br /> MSRPD mg/L 100.0 8.0% <_29.1 <br /> 300.0 05/02/2008:204745 CCB ppm 0.000 0.4 <br /> CCV ppm 20.00 96.3% 90-110 <br /> CCB ppm 0.000 0.4 <br /> CCV ppm 20.00 96.7% 90-110 <br /> CCB ppm 0.000 0.4 <br /> CCV PPM 20.00 106% 90-110 <br /> Nitrite 300.0 05/02/2008:204323 LCS mg/L 15.00 96.2% 90-110 <br /> MS mg/L 300.0 99.5% 91-121 <br /> MSD mg/L 300.0 108% 91-121 <br /> MSRPD m 100.0 7.9% X3.8 <br /> 300.0 05/02/2008:204745 CCB ppm 0.000 0.3 <br /> CCV ppm 15.00 101% 90-110 <br /> CCB ppm 0.000 0.3 <br /> CCV ppm 15.00 102% 90-110 <br /> CCB ppm 0.000 0.3 <br /> CCV PVM 15.00 97.3% 90-110 <br /> pH 4500-H B 05/29/2008:205274 Dup units 0.3% 4.80 <br /> 4500HB 05/29/2008:205819 CCV units 8.000 100% 95-105 <br /> CCV units 8.000 100% 95-105 <br /> Solids,Total Dissolved 2540 C,E 05/05/2008:204356 Blank mg/L 20 20 <br /> LCS mg/L 1000 101% 90-110 <br /> LCS mg/L 1000 100% 90-110 <br /> Dup I mgfL 1 1.0% 10.0 <br /> Sulfate 300.0 05/02/2008:204323 LCS mg/L 50.00 93.1% 90-110 <br /> MS mg/L 1000 97.8% 78-137 <br /> MSD mg/L 1000 110% 78-137 <br /> MSRPD m 100.0 11.5% :512.3 <br /> 100.0 05/02/2008:204745 CCB ppm 0.00 2 <br /> CCV ppm 50.00 98.6% 90-110 <br /> CCBppm 0.00 _ <br /> CCV m 50.00 98.1 Oil 90-110 <br /> Definition <br /> ICV :Initial Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification- Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted. The <br /> recoveries are an indication of how that sample matrix affects analyte recovery. <br /> Du :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate. The relative percent difference is an <br /> P indication of precision for the preparation and analysis. <br /> STK0834357:Quality Control Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.