VAPOR EXTRACTION TEST MONITORING DATA - WELL VW-3 <br /> RESNA Prol No 150047 01 I Project Manager John Lane Data Collected by SJ Date 10/22/93 <br /> Client Ekholm Property Site Escalon Address 1702 Jackson Street Data Checked by Jeanne Hornsey Test Unit <br /> 5hp Blower <br /> EXTRACTION WELL VW-3 DATA OBSERVATION WELL DATA <br /> Time Tata(Air Total Air Air Observed PIDfOVA Engine Vapor Sample VW2 vwl: <br /> Velocity Flow Rate Temperature Wellhead Conc Number <br /> Vacuum ,,. ., .. . <br /> Vacuum Vacuum Vacuum <br /> On H2O} Ian H2oj Ian H2O) <br /> (ft/min) MW (deg F} lm H20) fpPmk RPM <br /> 1420 5400 118 77 30 36 030 045 <br /> 14 25 5200 113 77 30 28 080 065 <br /> 1432 5200 113 77 30 31 to 1 0 <br /> 1436 5200 113 77 30 18 EP VEW3-30 min 10 1 05 <br /> 1450 5200 113 77 30 17 10 1 15 <br /> Distance from Extraction Well 31 5 24 <br /> I <br /> EKVET TBC <br /> 1 <br />