Laserfiche WebLink
Table 2 <br /> MONITORING DATA <br /> SOIL VAPOR EXTRACTION SYSTEM <br /> Ekholm Property <br /> 1702 Jackson Street <br /> Escalon,California <br /> Equivalent <br /> Date Monitoring FID Hexane Vacuum Temp Flow Rate System <br /> Point (ppmv) (ppmv) ("H20) (F) (scfm) Notes <br /> 9/15/95 VW-1 0 0 25 86 226 All 5 wells online <br /> 9/15/95 VW-2 13 42 42 81 242 All 5 wells online <br /> 9/15/95 VW-3 12 04 25 84 358 All 5 wells online <br /> 9/15/95 VW-4 18 58 46 77 57 All wells online <br /> 9/15/95 VW-5 40 128 49 90 109 All 5 wells online <br /> 9/15/95 Eff 1 13 42 NM 98 170 All 5 wells online <br /> 9/15/95 Eff 2 12 38 NM 141 146 All 5 wells online <br /> Notes <br /> Monitoring Point Respective monitoring/samphng point of well or system manifold <br /> FID Flame-ionization detector(calibrated to methane)measurement of collected vapor sample <br /> ppmv Parts per million by volume <br /> Equivalent Hexane FID measurement divided by 3125(rounded to tenths) <br /> Vacuum Vacuum measurement in inches water vacuum <br /> Temp Temperature measurement in degrees Farenheit(F) <br /> Flow Rate Flow rate in standard cubic feet per minute (scfm) <br /> NM Not measured <br /> i <br /> page 4 of 4 <br />