4 <br /> Preliminary Subsurface Investigation Report <br /> FORMER GRAYLIFT,INC. <br /> 3131 E. Fremont Street, Stockton, California <br /> 1.0. INTRODUCTION AND SCOPE OF WORK <br /> At the request of Mr. Dana Suntag, Advanced GeoEnvironmental, Inc. (AGE) has prepared this <br /> Preliminary Subsurface Investigation Report for the former Graylift, Inc. property located at 3131 <br /> E.Fremont Street,Stockton,California(site).The location of the site is illustrated in Figure 1;a site <br /> plan is shown in Figure 2. <br /> The scope of work included the advancement of nineteen soil probe borings and four hand-auger <br /> borings to investigate the potential release of petroleum hydrocarbons, selected metals,and volatile <br /> organic compounds (VOC's) in soil and ground water. This report is prepared in accordance with <br /> guidelines established by the Central Valley Regional Water Quality Control Board for investigation <br /> of underground storage tank(UST) sites. <br /> 2.0. BACKGROUND <br /> The site is located in San Joaquin County, in the city of Stockton. The site is located in an area of <br /> low topographic relief. <br /> Review of depth to ground water maps published by the San Joaquin County Flood Control and <br /> Water Conservation District for Fall 1998 indicates that ground water depths are approximately 55 <br /> feet below surface grade (bsg) near the site (Fall 1998). Depth to ground water in this area can be <br /> influenced locally and seasonally. <br /> AGE found information indicating that two underground storage tanks (USTs) had been removed <br /> from the site in December 1986, one 10,000-gallon unleaded gasoline UST and one 5,000-gallon <br /> diesel UST. During the UST removals, soil samples were collected from beneath each UST. The <br /> results of the laboratory analyses of the samples did not indicate a petroleum hydrocarbon-impact <br /> to soil in the former UST area; the PHS-EHD issued a No Further Action Letter on 10 February <br /> 1994. <br /> AGE also found information indicating that the southeast portion of the property was formerly <br /> utilized as a gasoline and service station by Shell Oil from approximately 1962 through 1973. <br /> Minimal documentation was found regarding the decommissioning of the station and UST system. <br /> At the request of Mr.Dana Suntag,representing Mr.Wiley Chandler,Advanced GeoEnvironmental, <br /> Inc.performed a preliminary subsurface investigation to assess for petroleum hydrocarbons,selected <br /> metals, and volatile organic compounds(VOCs)impacting soil and/or ground water resulting from <br /> unauthorized release(s)at 3131 E.Fremont Street, Stockton,California(site).Use of such materials <br /> Advanced GeoEnvironmental,Inc. <br />