i <br /> Project Status Update Report,Subsurface Investigation �--`-� <br /> Banner Island, Stockton, CA <br /> Septcmber 17, 1992 <br /> W060':.1 C <br /> The groundwater gradient beneath the two sites on August 7, 1992 was 0.017 ft/ft in a <br /> northwesterly direction. A groundwater gradient map is included as Figure 2. <br /> Groundwater samples were collected on August 7, 1992 from wells MW-1 through MW-9, after <br /> purging and stabilization of pH, electrical conductivity (EC), and temperature. Depth to water <br /> measurements ranged from 19.54 to 29.25 feet below the top of the well casings. Electrical <br /> conductivity measurements ranged from 802 to 1,577 µmhos/cm. The three samples with the <br /> highest electrical conductivity readings were submitted for analysis of total dissolved solids. All <br /> field work was performed in accordance with RESNA's Quality Assurance/Quality Control Plan <br /> (Attachment 1). Well purge logs are included in Attachment 2. <br /> Laboratory Analvsis <br /> Groundwater samples collected from wells MW-1 through MW-9 were analyzed for California <br /> Title 22 Metals; the samples collected from wells MW-7, MW-8, and MW-9 were also analyzed <br /> for Total Dissolved Solids (TDS) concentrations and the samples collected from wells MW-1 and <br /> MW-4 were submitted for Volatile. Organics utilizing EPA method 8240. <br /> Laboratory analysis indicated concentrations of priority pollutant metals above method detection <br /> limits in the groundwater samples collected from wells MW-1 through MW-9. Although none <br /> of the levels detected exceeded the maximum Soluble Threshold Limit Concentration (STLC) <br /> values as listed in Title 22 of the California Code of Regulations, several of the samples <br /> contained concentrations of arsenic (BI-MW-4), barium (BI-MW-3), selenium (BI-MW-1), and <br /> zinc (BI-MW-9) above the State Maximum Contaminant Level (MCL). TDS analytical results <br /> indicated that the samples collected from wells MW-7 (790 mg/f), MW-8 (1,100 mg/f), and <br /> MW-9 (690 mg/P) exceeds the recommended Secondary State Drinking Water Standard. No <br /> volatile organic analytes were detected in either sample MW-1 or MW-4 above the laboratory <br /> method detection limit. The laboratory results for the water samples are presented in Table 2. <br /> Laboratory reports, chain of custody documentation, and laboratory QA/QC data, are included <br /> in Attachment 3. <br /> Sampling of Adjacent Site <br /> One groundwater monitoring well located at the nearby Weber Point site (MW-5) was sampled <br /> on August 7, 1992. The Weber Point site is currently undergoing investigation and remediation <br /> of previous releases of petroleum hydrocarbons. This well was selected for sampling because <br /> it had no prior history of hydrocarbon impaction and is considered to be "clean". The Weber <br /> Point site is located approximately 1/4-mile east of the Banner Island Property (Figure 3). <br /> R EroRrsweo9o9sz.trn, 2 <br />