ARCHIVED REPORTS_REMEDIAL INVESTIGATION REPORT 2000
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
55
>
2900 - Site Mitigation Program
>
PR0009302
>
ARCHIVED REPORTS_REMEDIAL INVESTIGATION REPORT 2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2020 8:47:33 PM
Creation date
2/13/2020 2:23:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
REMEDIAL INVESTIGATION REPORT 2000
RECORD_ID
PR0009302
PE
2960
FACILITY_ID
FA0004002
FACILITY_NAME
MORTON-ALCO
STREET_NUMBER
55
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13737004
CURRENT_STATUS
01
SITE_LOCATION
55 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
808
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
07 February 2000 <br /> AGE-NC Project No. 95-0143 <br /> k. <br /> Page 3 of 5 <br /> surveyed casing elevation (Table 1). Between August and November 1999, ground water elevations <br /> decreased an average 1.03 feet. During the November 1999 monitoring event, ground water was <br /> within the screened interval of MW-16, MW-17. Ground water was from 0.2 feet to 6.6 feet above <br /> the screened interval in the remaining 7 monitoring wells. Ground water was within the screened <br /> intervals of each vapor well for free product determination. Measurable free product was not <br /> encountered at the site. The approximate hydraulic gradient was calculated to be 0.0008 ft/ft with <br /> a northeasterly flow direction on the subject property. Ground water elevation was higher in wells <br /> VW1 through VW4, indicating ground water mounding. Ground water elevation contours for the <br /> November 1999 monitoring event are illustrated in Figure 4. <br /> 3.2. ANALYTICAL RESULTS OF WATER SAMPLES <br /> During the November 1999 monitoring event,TPH-g was detected in samples collected from MW3, <br /> MW-6, MW-7 and MW-9 at concentrations of 210,000 parts per billion (ppb, reported as <br /> micrograms per liter), 1,400 ppb, 1,100 ppb and 14,000 ppb, respectively. BTEX compounds were <br /> detected in these wells at concentrations as high as 58,000 ppb (toluene in the sample from MW-3). <br /> Petroleum hydrocarbons were not detected in the samples collected from MW-10,MW-14,MW-15, <br /> MW-16 or MW-17. TBA was detected in the sample from MW-7 at a concentration of 6.4 ppb. <br /> Other oxygenates were not detected at the site during the November 1999 sampling event. <br /> Measurable free product was not encountered in any of the wells on the site. Analytical results of <br /> ground water samples collected during the November 1999 monitoring event are summarized on <br /> Table 2. Analytical results of historical ground water samples are summarized on Tables 3 and 4. <br /> The laboratory report (MAI Laboratory I. D. Nos. 25492-25500) and chain-of-custody forms are <br /> included in Appendix B. <br /> The concentration of dissolved oxygen in ground water remained generally stable at the site relative <br /> to previous monitoring events. Dissolved oxygen data are summarized on Table 5. <br /> 3.3. OPERATION OF SVE/IAS UNITS <br /> The SVE system operated at a capacity of approximately 278 cubic feet per minute (cfm) with a <br /> burner temperature maintained near 1450°F. The lower explosive limit (LEL) of the intake gas <br /> stream was approximately 5 to 6 percent. <br /> Field measurements of flow, vacuum and organic vapor concentration in the air stream from each <br /> extraction well were measured on a periodic basis. Due to the tight soil formation and limited screen <br /> interval, a vacuum of near 50 inches of water was maintained on wells VW 1,VW2,VW3 and VW5 <br /> Advanced GeoEnvironmental,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.