Laserfiche WebLink
01 October 2019 <br />AGE Project No. 19-4850 <br />Page 12 of 14 <br />denitrify the concentrations by approximately 30 percent and less desirable soils with <br />more sands and faster percolation rates (less moisture and clay content) denitrify only <br />about 10 percent. <br /> <br />A denitrification factor of 25 percent was selected for the calculation based on the silty <br />clayey fine-grained sand soil existing at the site. <br /> <br /> <br />9.6. MASS BALANCE OF NITROGEN LOADING <br /> <br />The EHD requires the user to consider all potential sources identified for wastewater <br />generation. Further, the EHD supports the use of Hantzsche/Finnemore, or other <br />appropriate formula/model to calculate a mass of nitrogen loading. <br /> <br />COMMERCIAL: <br /> <br />The Hantzsche / Finnemore (Nr) equation for residential home application: <br />Nr = I x Nw (1-d) + R x Nb ÷ (I+R) <br />Definitions: <br /> <br />Nr = The average concentration of nitrate-nitrogen in the recharged waste water parts per <br />million of nitrate-nitrogen. <br /> <br />I = Volume rate of wastewater entering the soil averaged over the gross developed area <br />(acres) in inches per year. The total wastewater volume for proposed project will be <br />240 gpd (existing system/use) + 80 gpd (added future use) x 260 days of proposed <br />operation = 320 x 260 days ÷ 7.48 gallons per cubic foot = 11,123 cubic feet of <br />wastewater. Does not account for evapotranspiration likely to occur. <br /> <br />NW = Total nitrogen concentration of wastewater at 45 mg/L-N based on the average <br />discharge. Accounting for the loss of mg/L-N in the septic tank at 15% = 45-15%= 38.25 <br />and the loss from the biomat at 10% 38.25 - 10% = 34.425 mg/L-N <br /> <br />d = Fraction of nitrogen concentration removed from the wastewater due to denitrification <br />within the soil (25 percent for clayey loam/loamy clay type soils). <br />R = Estimated Deep percolation / average rainfall recharge rate per year: 3.72 inches. <br />Nb = Background nitrate-nitrogen concentration of rainfall recharge: 1.0 mg/l. The Nb is <br />an average value determined for San Joaquin County by the EHD. <br /> <br />COMMERCIAL CALCULATIONS: <br /> <br />Nr = I x Nw (1-d)+ R x Nb ÷ (I+R) <br /> <br /> <br />