Laserfiche WebLink
Lancaster <br /> Laboratories Analysis Report <br /> 2425 New Holland Pike,PO Box 12425,Lancaster,PA 17605-2425•717-658.2300 Fax:717-656-2681•www.lancasterlabs.com <br /> Page 3 of 3 <br /> REPRINT <br /> Quality Control Summary <br /> Client Name: ChevronTexaco Group Number: 901068 <br /> Reported: 08/06/04 at 12:25 PM <br /> Batch number: R041821AA Surrogate Quality Control <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 4298366 93 99 90 94 <br /> Blank 94 98 94 92 <br /> LCS 98 105 96 95 <br /> MS 94 97 91 91 <br /> MSD 96 102 93 94 <br /> Limits: 70-129 70-121 70-130 70-128 <br /> Analysis Name: BTEX+MTBE by 8260B <br /> Batch number: X041751AB <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-de 4-Bromofluorobenzene <br /> 4298364 113 109 118 110 <br /> 4298365 116 109 118 112 <br /> Blank 114 116 117 112 <br /> LCS 116 114 120 114 <br /> MS 115 109 121 112 <br /> MSD 114 108 121 113 <br /> Limits: 70-129 70-121 70-130 70-128 <br /> *-Outside of specification <br /> (1) The result for one or both determinations was less than five times the LOQ. <br /> (2) The background result was more than four times the spike added. <br />