My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_1985
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
INSTALL_1985
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 11:28:42 AM
Creation date
2/19/2020 9:42:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1985
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARROW TANK WORKS <br /> 1701 SOUTH BARNEY STREET <br /> Mailing Address: P.O. Box 563 <br /> ANDERSON, CALIFORNIA 96007 <br /> PHONE (916) 365-5434 <br /> We respectfully offer the following information on our dual containment, <br /> fiberglass coated, underground steel storage tanks for storage of flammable <br /> and combustible liquids: <br /> These tanks are fabricated of sheet or plate steel in conformance with the <br /> latest edition of Underwriters' Laboratories, Inc. Standard For Safety UL58 and <br /> ANSI B 137.1-1971 . They may be used to comply with the storage of hazar- <br /> dous liquids including NFPA#30 and #31, and also the Uniform Fire Code. They <br /> must be installed in accordance with these specifications as well as the O.S.H.A. <br /> Fire Code and local site requirements. <br /> We prepare the exterior of our steel tanks by sandblasting to an SSPC-10 <br /> finish prior to coating. We then spray coat with polyester resin, apply glass- <br /> reinforced isophthalic resin mat and a final coat of polyester resin of sufficient <br /> thickness to 35,000 volt test. <br /> Nylon dialectric bushings are installed to isolate the tanks from piping and <br /> stray current. Our final product assures the integrity required for external cor- <br /> rosion protection and electrical insulation. <br />
The URL can be used to link to this page
Your browser does not support the video tag.