My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 2:01:21 PM
Creation date
2/19/2020 10:04:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 05/23/1 <br /> Facility Address: 419 S. Main St., Manteca Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> ROUTINE ANNUAL INSPECTION AND MONITORING SYSTEM CERTIFICATION <br /> Violations: (13, 17, 24) <br /> 13. The Bravo box float and chain in the UDC 3/4 for the diesel piping failed to stop the flow of product at <br /> the dispenser when tested. All monitoring equipment shall be maintained to activate an audible and <br /> visual alarm or stop the flow of product at the dispenser when it detects a leak. The service technician <br /> adjusted the float and verified functionality. <br /> 17. The 91 line leak detector failed to detect a leak when tested. All line leak detectors shall be capable <br /> of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, <br /> retested it, and it passed. <br /> 24. Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on May 28, 2010 and a test report has not been submitted to the EHD. A copy of the test <br /> report must be submitted within 30 days of the tests. Immediately submit a copy of the test report to the <br /> EHD. <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by June 23, 2011 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork <br /> Note: The Response Plan was completed and approved at the time of inspection. A copy was left o. <br /> site. <br /> Note: The plastic handle from a vehicle window squeegee was found at the bottom of the drop tube for <br /> the 87 tank. It did not appear to be interfering with the mechanical flapper at the time of inspection. The <br /> handle was removed from the tank by the technician on site. Mechanical flappers are used as overfill <br /> prevention at this facility. The overfill prevention systems must be maintained and fully functional at all <br /> times. <br /> Note: The financial responsibility documents for this facility were last submitted to the EHD in May 2010. <br /> Copies of current financial responsibility documents are due this month. <br /> lrovided: Return to Compliance Certification form, Response Plan form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By� Title: <br /> � <br /> . <br /> EHD 23-02-00 ev 08/10/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.