Laserfiche WebLink
EURO PROTOCOL PREFI?' AUTO DIHL TIME SETUP: <br /> S <br /> NONE <br /> SYSTEM SECURITY <br /> CODE : 000000 <br /> MANTECA EXPRESS MART CUSTOM ALARM LABELS <br /> 419 S MAIN ST DISABLED <br /> MANTECA <br /> CA <br /> MAY 23, 2,011 9:52 <br /> SYSTEM STATUS REPORT_ _ RS-232 END OF MESSAGE <br /> T I :DELIVERY NEEDED DISABLED <br /> AUTO DIAL ALARM SETUP <br /> COMMUNICATIONS SETUP - - - - - - - - - - - - <br /> PORT SETTINGS: <br /> COMM BOARD I (RS-232) <br /> BAUD RATE 9600 <br /> PARITY NONE <br /> SYSTEM SETUP STOP BIT 1 STOP <br /> _ _ _ _ DATA LENGTH: 8 DATA <br /> MAY 23, 2011 9:52 - RS-232 SECURITY <br /> CODE : DISABLED IN-TANK SETUP <br /> - - - - - - - - - - - - <br /> COMM BOARD 2 (FXMOD) <br /> SYSTEM UNITS BAUD RATE : 2400 T 1 :PREM <br /> PARITY ODD PRODUCT CODE 1 <br /> U.S. STOP BIT 1 STOP THERMAL COEFF : .000700 <br /> SYSTEM LANGUAGE DATA LENGTH: 7 DATA TANK DIAMETER 95.50 <br /> SFORMAT ENGLISDATEiTIME FRS-232 SECURITY TANK PROFILE 1 FT <br /> MON DD YYYY HH:MM:OR CODE : DISABLED FULL VOL 10000 <br /> DIAL TYPE TONE <br /> MANTECA EXPRESS MARTANSWER ON : 1 RING <br /> 419 S MAIN ST MODEM SETUP STRING FLOAT SIZE: 4.0 IN. <br /> MANTECA DIAL TONE INTERVAL: 32 WATER WARNING 3.0 <br /> CA HIGH WATER LIMIT: 3.0 <br /> 1 <br /> SHIFT TIME DISABLED COMM BOARD 3 (RS-232? <br /> SHIFT TIME I DISABLED BAUD RATE 9600 MAX OR LABEL VOL: 10000 <br /> SHIFT TIME 3 DISABLED PARITY ODD OVERFILL LIMIT 90i <br /> SHIFT TIME 4 DISABLED STOP BIT I STOP 9000 <br /> DATA LENGTH: 7 DATA HIGH PRODUCT 95% <br /> TANK PER TST NEEDED WRN RS-232 SECURITY 9500 <br /> DISABLED CODE : DISABLED DELIVERY LIMIT 25% <br /> TANK. ANN TST NEEDED WRN 2500 <br /> DISABLED AUTO TRANSMIT SETTINGS: LOW PRODUCT 600 <br /> LINE RE-ENABLE METHOD LEAK ALARM LIMIT: 99 <br /> AUTO LEAK ALARM LIMIT SUDDEN LOSS LIMIT: 99 <br /> PASS LINE TEST <br /> DISABLED TANK TILT 0.00 <br /> LINE PER TST NEEDED WRNAUTO HIGH WATER LIMIT PROBE OFFSET 4.00 <br /> DISABLED DISABLED <br /> AUTO OVERFILL LIMIT <br /> LINE ANN TST NEEDED WRN <br /> DISABLED DISABLED SIPHON MANIFOLDED TANKS <br /> AUTO LOW PRODUCT TO: NONE <br /> PRINT TC VOLUMES DISABLED LINE MANIFOLD£D TANKS <br /> ENABLED AUTO THEFT LIMIT TO: NONE <br /> DISABLED <br /> TEMP COMPENSATION AUTO DELIVERY START <br /> o <br /> VALUE (DEG F ) : 60.0 DISABLED LEAK MIN PERIODIC: O <br /> STICK HEIGHT OFFSET AUTO DELIVERY END p <br /> DISABLED <br /> DISABLED <br /> AUTO EXTERNAL INPUT ON LEAK MIN ANNUAL Of <br /> H-PROTOCOL DATA FORMAT DISABLED <br /> DERNAL INPUT OFF 0 <br /> AUTO EXTHEIGHT DISABLED <br /> DAYLIGHT SAVING TIME AUTO SENSOR FUEL ALARM PERIODIC TEST TYPE <br /> ENABLED DISABLED STANDARD <br /> START DATE AUTO SENSOR WATER ALARM <br /> APR WEEK I SUN DISABLED ANNUAL TEST FAIL <br /> START TIME AUTO SENSOR OUT ALARM ALARM DISABLED <br /> 2:00 AM DISABLED <br /> END DATE PERIODIC TEST FAIL <br /> OCT WEEK 6 SUN ALARM DISABLED <br /> END TIME <br /> 2:00 AM GROSS TEST FAIL <br /> RE-DIRECT LOCAL PRINTOUT RECEIVER SETUP: ALARM DISABLED <br /> DISABLED ANN TEST AVERAGING: OFF <br /> NONE PER TEST AVERAGING: OFF <br />