My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2010 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 2:01:21 PM
Creation date
2/19/2020 10:04:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2018
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 05-28-10 <br /> Facility Address: 76 Express Market 419 South Main Street, Manteca Program: UST <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Annual Monitoring System Certification testing <br /> #15. Product 91 spill container's secondary containment is not tight. The 91 spill container failed the one <br /> hour hydrostatic test. Correct by repairing the 91 spill containment into proper functioning order. Contact <br /> SJC EHD if a permit is needed for repair. A re-inspection of the testing of the 91 spill containment is <br /> required and will be charged at the currently hourly rate. Submit a 48 hour test notification of the re- <br /> testing to SJC EHD. <br /> #23c. Designated operator (D.O.) failed to document correct test dates on the monthly visual inspection <br /> report. The secondary containment testing (SB-989) was conducted 05-11-09. On the D.O. monthly <br /> report for May — August 2009, the secondary containment test date was written as 03-14-2006. D.O. <br /> Correct by ensuring all required test dates are correctly written in the D.O. monthly reports. <br /> Submit to SJC EHD by 06-28-10: <br /> 1. one copy of the completed `Return to Compliance Certification' <br /> 2. a corrective action statement for the above violations <br /> Notes: <br /> 1. Received copy of the Certification of Financial Responsibility and letter from Chief Financial <br /> Officer <br /> 2. Received copy of Secondary containment test results from 05-11-09. UST system all passed <br /> except Dispenser 3-4 but was re-tested 06-1-09 and passed. <br /> 3. A Monitoring System Certification (MSC) test was conducted 04-09-2008. The following MSC test <br /> was conducted last year 05-08-2009. Facility converting from Quick Stop facility to 76 facility. <br /> Gas pumps under construction caused delay in MSC testing. Ensure future MSC are performed <br /> in a timely manner, due every 12 months. <br /> 4. Secondary containment testing (SB 989) was recently performed 05-11-2009. The previous <br /> secondary containment testing was performed 03-14-2006. Facility converting from Quick Stop <br /> facility to 76 facility. Gas pumps under construction caused delayed in SB-989 testing. Ensure <br /> future secondary containment tests are performed in a timely manner, due every 36 months. Next <br /> due by 05-2012. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($115). <br /> THIS FACT TY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By. Title: WO VIA <br />
The URL can be used to link to this page
Your browser does not support the video tag.