My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UL/ULC Listed Red ,tread® IIA Piping SystE I <br /> RED THREAD IIA PIPING RED THREAD IIA <br /> RED THREAD IIA Primary Piping Secondary Containment Piping <br /> Nom. Pipe Size Part Number Pipe Length Nom. Pipe Size Part Number Pipe Length <br /> (in.) mm (ft.) (In.) mm (ft.) <br /> 2 50 011020-069-1 15 3 80 011030-069-4 15 <br /> 2 50 011020-069-2 22-25 3 80 011030-069-5 22-25 <br /> 2 50 011020-069-3 26-30 3 80 011030-069-6 26-30 <br /> 3 80 011030-069-1 15 4 100 011040-077-5 15 <br /> 3 80 011030-069-2 22-25 4 100 011040-069-5 22-25 <br /> 3 80 011030-069-3 26-30 4 100 011040-077-6 26-30 <br /> 4 1 100 011040-071-1 15 6 150 011060-120-5 15 <br /> 4 1 100 011040-069-2 22-25 6 150 011060-120-4 22-25 <br /> 4 100 011040-071-3 26-30 6 150 011060-120-6 26-30 <br /> DIMENSIONAL DATA <br /> Nominal Nominal External Pressure <br /> Pie Nominal Nominal Wall Nominal Pressure/ Mill Test Max. Rating <br /> Pipe Weight Temperature Pressure I.D. O.D. (psig/ <br /> Size (In./ Thickness (p g ) <br /> (in./ ) (In.! ) (InJmm) (lbs./ft./ ) Max. Rating (psig/,,?a) 750F124°C 150°F/660C <br /> 2 2.235 2.375 .070 0.5 250 psig @ 150'F 375 85 80 <br /> 3 3.360 3.500 .070 0.7 175 psig @ 150°F 300 36 34 <br /> 4 4.360 4.560 .085 1.2 125 psig @ 150'F 265 34 30 <br /> 6 6.408 6.678 .135 2.4 20 psig @ 150-F 265 22 20 <br /> RED THREAD IIA Pie Bending Radius, Minimum <br /> PROPERTY psi @ 75'F psi @ 150'F Nominal <br /> Axial Tensile(ASTM D2105) Pipe Size 2" 3" 4" 6" <br /> Ultimate Stress 10,300 71.0 8.200 56.5 (inches) <br /> Design Stress 2,575 17.8 2.050 14.1 Ft. 75 110 140 204 <br /> Modulus of Elasticity 1.82 x 106 1.42 x 106 m 21.3 33.5 42.7 62.2 <br /> Axial Compression (ASTM D695) (1) All values except pressure-temperature <br /> Ultimate Stress 33,300 230.0 25,600 177.0 maximum rating are nominal values_Tolerances <br /> Design Stress 8,300 57.2 6.400 44.1 or maximumimmimum limits can be obtained <br /> Modulus of Elasticity1.26 x 106 - .89 x 106 from Smith Fibercast <br /> (2) All sizes can accept full vacuum pressures <br /> Beam Bending(SFPTM) at maximum temperature ratings <br /> Ultimate Stress 23,000 159.0 19.200 132.0 (3) ultimate and allowable design stresses are <br /> Design Stress(4) 2.900 20.0 2.400 16,5 based on minimum reinforced wall thickness <br /> g Pipe is manufactured in compliance with ASTM <br /> Modulus of Elasticity 2.18 x 106 15031 1.70 x 106 11721 D2996 <br /> (Long Term eerASTM D2925) (4) Design bending stress is 1-6 of ultimate to <br /> Hydrostatic Burst(ASTM D1599) acc sunt for combined stress (i a bending and <br /> Ultimate Hoop (5) Design stress is based on long term cyclic <br /> Tensile Stress 34,000 i 39,200 fatigue data using ASTM D2992 test method <br /> However, all testing is not complete at time of <br /> Hydrostatic Design(ASTM D2992) 2"-3" 2 &3" 2-&3" 2 u printing <br /> Procedure A 9.410(5) 64.9(5) 7,400(7) 51(8) (s) For RED THREAD IIA pipe the hydrostatic <br /> Cyclic 150 x 106 4"-6" 4"-6" 4--6" 4"-6" cyclic design stress was determined at 1501 and <br /> Cycles 13,040(6) 399(6) 10,450 72.1 200°F, per ASTM D2992 Procedure A Based <br /> y on this data,the extrapolated value at 75`F is <br /> Coefficient of Linear 0.88 x 10-5 indin./'F 13,030 psi. <br /> Thermal Expansion(SFPTM) 1.58 x 10' (7) For RED THREAD IIA pipe the hydrostatic <br /> eCI(IC Gravity 1 8 cyclic design stress was determined at 75°and <br /> S <br /> p ty 200°F, per ASTM D2992 Procedure A Based <br /> Flow Factor on this data,the extrapolated value at 150`F is <br /> Hazen-Williams Coefficient 150 7.400 psi <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.