Laserfiche WebLink
SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> ` This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br /> printouts from tests(if applicable)should be provided to the facility owner/operator for submittal to the local regulatory agency. <br /> 1. FACILITY INFORMATION <br /> Facility Name: BOYETT PETROLEUM#5-MANTECA EXPRESS Date of Testing: APRIL 12, 2007 <br /> Facility Address: 419 S MAIN STREET, MANTECA, CA 95336 <br /> Facility Contact: BOBBY MANGAT I Phone: (209)239-7978 <br /> Date Local Agency Was Notified of Testing: MARCH 29,2007 <br /> Name of Local Agency Inspector(if present during testing): <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name: TANK-TEK ENVIRONMENTAL CORPORATION <br /> Technician Conducting Test: ROB NEIMEYER <br /> Credentials': ® CSLB Contractor ❑ ICC Service Tech. ❑ SWRCB Tank Tester ❑ Other(Spec) <br /> License Number(s): 803705 <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ®Hydrostatic ❑Vacuum ❑ Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Identify Spill Bucket(By Tank 1 2 3 4 <br /> Number, Stored Product, etc.) SUPER REGULAR DIESEL <br /> Bucket Installation Type: ® Direct Bury ® Direct Bury ®Direct Bur} ❑ Direct Bury <br /> ❑ Contained in Sump ❑ Contained in Sump ❑ Contained in Sump ❑Contained in Sump <br /> Bucket Diameter: 10.50" 10.50" 10.50" <br /> Bucket Depth: 12.00" 12.00" 13.00" <br /> Wait time between applying 0 0 0 <br /> vacuum/water and start of test: <br /> Test Start Time(TI): 10:30 AM 10:30 AM 10:30 AM <br /> Initial Reading(RI): 12.00" 12.00" 13.00" <br /> Test End Time(TF): 11:00 AM 11:00 AM 11:00 AM <br /> Final Reading(RF): 12.00" 12.00" 13.00" <br /> Test Duration(TF—Tj): 30 MINUTES 30 MINUTES 30 MINUTES <br /> Change in Reading(RF-RI): 0 0 0 <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑Fail ❑ Pass ❑ Fail <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate, and in full compliance with legal requirements. <br /> Technician's Signature: "_'� Date: APRIL 12,2007 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br /> may be more stringent. <br />