My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:59:42 PM
Creation date
2/19/2020 10:50:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Piping information continued- <br /> Check <br /> heck <br /> Box Code <br /> Section <br /> 25290.1(x)(1) Piping compatible with material intended to be stored. <br /> 25290.2(c)(1) <br /> 23 CCR Design and construction of piping approved by independent testing organization(e.g.UL). <br /> 2631 <br /> Piping,including vent lines,sloped toward tanks with minimum 1/4 inch slope per 1 foot of run. <br /> HSC <br /> O 25290.1(k) <br /> 25290.20&0) Va or recovery,fill riser,and vent line piping are secondarily contained. <br /> G. OVERSPILL/OVERFILL PREVENTION: <br /> Check <br /> Box Code <br /> Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> 2635(b) Manufacturer Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> Restrict delivery of flow to the tank at least 30 minutes before the tank overfills,provided the <br /> restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an audible <br /> ❑ 23 CCR alarm at least five minutes before the tank overfills <br /> 2635(b)(2) <br /> Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer Model <br /> H. CORROSION PROTECTION: <br /> Check <br /> Box Code <br /> Section <br /> Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: Steel with cathodic protection or impressed current <br /> 23 CCR 2636(6) Steel isolated from contact with backfill <br /> FRP or equivalent non-metallic exterior coatings or coverings <br /> 4/1 Tank corrosion protection: Sacrificial Anode <br /> Ll23 CCR 2635(ax2) P Steel tank with field installed cathodic protection or impressed <br /> Current <br /> ❑ Tie-downs,when used,constructed of non-corrosive material or coated steel. <br /> Revised 07/31/08 7 <br />