My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985 - 2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
419
>
2300 - Underground Storage Tank Program
>
PR0231433
>
COMPLIANCE INFO_1985 - 2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2020 4:57:00 PM
Creation date
2/19/2020 11:53:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985 - 2004
RECORD_ID
PR0231433
PE
2361
FACILITY_ID
FA0003685
FACILITY_NAME
DBA CIRCLEK, REFUEL PETROLEUM INC.
STREET_NUMBER
419
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21938610
CURRENT_STATUS
01
SITE_LOCATION
419 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
229
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUBLIC HEALTH SERVICES SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DIVISION <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209) 468-3420 <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Name <br /> Facility Address R19. <br /> Facilty Contact itle Phone No. <br /> Program ID# P Number of UST(s) <br /> UST#/Product — D <br /> Overfill Prevention: Au ' le an Visual echanica <br /> Piping system: Gravity Pressure f Suction L <br /> Monitoring system v• No <br /> Automatic pump shutdown satisfies CCR2636 (g): Yes <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health& Safety Code <br /> (HSC) and/or California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate <br /> 2 HSC 25292.3 Upgrade compliance certificate/sticker <br /> 3CR 2711(b) &(c) Current State Form A&B <br /> 4 HSC 25292.2 Certification of financial responsibility and letter from chief financial <br /> officer <br /> 5 CCR 2630 (d) Continuous monitoring system for UST system <br /> 6 CCR 2636 (c)(1) All releases in secondary piping now to a collection sump <br /> 7 CCR 2636 (a) Secondary containment for piping is waterproof <br /> 8 CCR 2636(f)(2) Automatic line leak detector(s) <br /> 9 CCR 2636 (f)(1) Continuous monitoring system for underground piping <br /> 10 CCR 2632 (c)(2) Continuous monitoring system for UST <br /> 11 HSC 25291(a)(2) Secondary containment for UST is tight <br /> 12 CCR 2636 (f)(1) Continuous monitoring system for dispenser system <br /> 13 CCR 2635 (b)(1) Spill container <br /> 14 CCR 2635 (b)(2) Overfill prevention system <br /> 15 CCR 2631 (a) Primary containment is product-tight <br /> 16 HSC 25292.1 UST system is operated to prevent unauthorized release <br /> 17 CCR 2650 Recording/reporting unauthorized release <br /> 18 CCR 2632 (d) Monitoring and response plan <br /> 19 CCR 2712 (i) Monitoring and response plan is on site <br /> 20 CCR 2712 (b) Maintenance and monitoring records <br /> 21 CCR 2636 (f)(4) Annual line tightness test <br /> 22 CCR 2630 (d) Annual line leak detector test <br /> 23 CCR 2630 (d) Annual monitoring certification <br /> 24 CCR 2643 (d) Daily monitoring of suction piping that is not continuously <br /> monitored <br /> loft <br /> PHS 260(8/04/00) <br />
The URL can be used to link to this page
Your browser does not support the video tag.