My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_SEMI-ANNUAL GROUNDWATER MONITORING REPORT AUGUST 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
9508
>
2900 - Site Mitigation Program
>
PR0516935
>
ARCHIVED REPORTS_SEMI-ANNUAL GROUNDWATER MONITORING REPORT AUGUST 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2020 3:50:57 PM
Creation date
2/21/2020 1:32:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
SEMI-ANNUAL GROUNDWATER MONITORING REPORT AUGUST 2010
RECORD_ID
PR0516935
PE
2960
FACILITY_ID
FA0012937
FACILITY_NAME
MONIER LIFETILE LLC
STREET_NUMBER
9508
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19321003
CURRENT_STATUS
01
SITE_LOCATION
9508 S HARLAN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
amen <br /> TABLE 2 <br /> GROUNDWATER ANALYTICAL RESULTS - LATHROP FACILITY <br /> Well Sample ID Date TPH-Diesel Total Cr Dissolved Cr Dissolved Cr VI <br /> Identification Sampled Method 8015M Method 6010 Method 6010 Method 7199 <br /> Units /L /L /L /L <br /> CDPH MCL -- 50 50 50 <br /> RWQCB WQG 100 50 50 50 <br /> LPW-3 LPW-3 11/23/09 <50 <10 <10 3.7 J4 <br /> (cont.) LP-D-112309 11/23/09 <50 <10 <10 4.3 J4 <br /> LPW-3 12/22/09 <50 <10 <10 3.5 <br /> LP-D-122209 12/22/09 <50 <10 <10 3.4 <br /> LPW-3 01/26/10 <50 <10 <10 2.9 <br /> LP-D-012610 01/26/10 <50 <10 <10 2.8 <br /> LPW-3 02/17/10 <50 <10 <10 7.1 <br /> LP-D-021710 02/17/10 <50 <10 <10 6.8 <br /> LPW-3 08/25/10 <50 3.2 J <10 5.6 <br /> LP-D-082510 08/25/10 <50 3.0 J <10 4.9 <br /> Reporting Limit 50 10 10 1 0.5 <br /> Method Detection Limit --- 3 3 0.2 <br /> Notes: <br /> 1.Analysis conducted by Agriculture and Priority Pollutants Laboratories,Inc.(APPL,Inc.)in Clovis,California. <br /> TPH-diesel=diesel range total petroleum hydrocarbons. <br /> Cr=chromium. <br /> Cr VI=hexavalent chromium(or Chromium VI). <br /> ug/L=micrograms per liter. <br /> CDPH MCL=California Department of Public Health Maximum Contaminant Level for Cr in drinking water. <br /> WQG=Water Quality Goal,Central Valley Regional Water Quality Control Board(RWQCB). <br /> <=not detected at or above the Reporting Limit(RL)or Method Detection Limit(MDL). <br /> J=estimated concentration between the RL and MDL. <br /> J1 =estimated value;sample was analyzed outside the holding time for Cr VI by the laboratory. <br /> J2=estimated value;the percent recovery of the MS and MSD are above the laboratory control limits;therefore,the sample results <br /> are estimated and potentially biased high. <br /> J3=estimated concentration due to the absolute difference between the primary and duplicate results which exceeds the reporting limit <br /> (Relative Percent Difference or RPD not calculated because the result for the primary sample is less than 5 times the reporting limit). <br /> J4=estimated value;the percent recovery of the MS and MSD are below the laboratory control limits;therefore,the sample results <br /> are estimated and potentially biased low. <br /> G=sample was reported by URS to be cloudy and the initial analytical result for Total Cr was 120 ug/L. Due to turbidity,the sample was <br /> centrifuged and filtered through 47 mm glass fiber filter prior to digestion and reanalysis. Total Cr concentration after reanalysis <br /> was reported at 13 ug/L. <br /> G1 =sample was reported by URS to be highly turbid and the initial reported analytical result for Total Cr was 770 ug/L. Due to turbidity, <br /> the sample was centrifuged and filtered through 47 mm glass fiber filter prior to digestion and reanalysis. Total Cr concentration after <br /> reanalysis was reported at 8 J ug/L. <br /> W=weathered diesel or other petroleum hydrocarbons with higher boiling points. <br /> Bold=concentrations exceed screening criteria. <br /> Listed data before June 2005 are from the URS Semi-Annual Groundwater Report(November 2004&December 2004). <br /> AMEC Geomatrix, Inc. <br /> P:\10626.000.0\Docs\Semi-Annual Groundwater Monitoring&Sampling\Semi-Annual 1-10\Table 2 Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.