Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HEINZ
>
2847
>
2900 - Site Mitigation Program
>
PR0521477
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2020 3:54:01 PM
Creation date
2/21/2020 1:44:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0521477
PE
2950
FACILITY_ID
FA0014584
FACILITY_NAME
UP RR ACE EQUIPMENT MAINT FACILITY
STREET_NUMBER
2847
STREET_NAME
HEINZ
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16707008
CURRENT_STATUS
01
SITE_LOCATION
2847 HEINZ ST
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DIATOMACEOUS EARTH, ETC. SHOVEL UP AND DISPOSE. PREVENT SPILLS FROM EN TERING <br /> STORM SEWERS, DRAINS, SOIL. REPORT SPILLS AS REQUIRED TO AUTHORITIES. U.S. <br /> COAST GUARD REQUIRES IMMEDIATE REPORTING OF SPILLS THAT COULD REACH ANY <br /> WATERWAY INCLUDING INTERMITTENT (SEE BELOW) . <br /> Neutralizing Agent: (FROM ABOVE) DRY CREEKS. REPORT SPILL TO COAST GUARD TOLL <br /> FREE (800-424-8802) ; ROAD SPILLS NOTIFY CHEMTREC. <br /> Waste Disposal Methods: PRODUCT IS SUITABLE FOR BURNING FOR FUEL VALUE IN <br /> COMPLIANCE WITH APPLICABLE LAWS AND REGULATIONS.DISPOSAL OF UNUSED PRODUCT <br /> MAY BE SUBJECT TO RCRA REGULATIONS (40 CFR 261) DUE TO BENZENE (2.320, TCLP , <br /> FLASH<-40F) . DISPOSAL OF USED PRODUCT MAY ALSO BE REGULATED DUE TO <br /> IGNITABILITY, CORROSIVITY, REAC TIVITY, OR TOXICITY AS DETERMINED BY TCLP. <br /> Handling And Storage Precautions: NEVER SIPHON GASOLINE BY MOUTH AND DO NOT USE <br /> AS A SOLVENT OR CLEANING AGENT. USE NON-SPARKING TOOLS AND EXPLOSION-PROOF <br /> EQUIPMENT. USE IN WELL VENTILATED AREAS AWAY FROM IGNITION SOURCES. PORTABLE <br /> CO NTAINERS MUST BE PLACED ON GROUND AND NOZZLE KEPT IN CONTACT WHEN FILLING <br /> TO PREVENT STATIC SPARKS. <br /> Other Precautions: DRUMS MUST BE GROUNDED AND BONDED AND EQUIPPED WITH <br /> SELF-CLOSING VALVES, PRESSURE VACUUM BUNGS, AND FLAME ARRESTERS. STORE AWAY <br /> FROM IGNITION SOURCES IN A COOL AREA EQUIPPED WITH AUTOMATIC SPRINKLING <br /> SYSTEM. OUTSIDE OR DETACHED STORAGE PREFERRED. STORAGE CONTAINERS SHOULD BE <br /> GROUNDED AND BONDED. <br /> ------------------------------------------------------- <br /> ------------------------------------------------------- <br /> Fire and Explosion Hazard Information <br /> ------------------------------------------------------- <br /> ------------------------------------------------------- <br /> Flash Point Method: TCC <br /> Flash Point: <-40.C, -40.F <br /> Lower Limits: 1.4 <br /> Upper Limits: 7.6 <br /> Extinguishing Media: CARBON DIOXIDE, FOAM, DRY CHEMICAL, WATER FOG. NFPA HAZARD <br /> ID: HEALTH: 1; FLAMMABILITY: 3; REACTIVITY: 0. <br /> Fire Fighting Procedures: FOR FIRES IN ENCLOSED AREAS, FIRE FIGHTERS MUST USE <br /> SELF-CONTAINED BREATHING APPARATUS. FOR LARGE SPILLS, FOAM IS THE PREFERRED <br /> AGENT; BLANKETING THE GASOLINE SURFACE. WATER SPRAY MAY BE USED TO FLUSH <br /> SPILL AWAY FROM EXPOSURE; PREVENT SPREADING GASOLINE INTO SEWERS, STREAMS, <br /> DRINKING WATER SUPPLIES. <br /> Unusual Fire/Explosion Hazard: EXTREMELY FLAMMABLE. VAPOR ACCUMULATION COULD <br /> FLASH AND/OR EXPLODE IF IN CONTACT WITH OPEN FLAME. IF SPILL HAS NOT IGNITED, <br /> ADD FOAM BLANKET TO SUPPRESS RELEASE OF VAPORS. IF FOAM NOT AVAILABLE, A WAT <br /> ER SPRAY CURTAIN CAN BE USED TO DISPERSE VAPORS AND PROTECT PERSONNEL <br /> ATTEMPTING TO STOP THE LEAK. <br /> ------------------------------------------------------- <br /> ------------------------------------------------------- <br /> Control Measures <br /> ------------------------------------------------------- <br /> ------------------------------------------------------- <br /> Respiratory Protection: APPROVED RESPIRATORY EQUIPMENT MUST BE USED WHEN <br /> AIRBORNE CONCENTRATIONS ARE UNKNOWN OR EXCEED THE TLV. <br /> Ventilation: USE IN WELL VENTILATED AREA WITH LOCAL EXHAUST VENTILATION. <br /> VENTILATION REQUIRED AND EQUIPMENT MUST BE EXPLOSION PROOF. USE AWAY FROM ALL <br /> IGNITION SOURCES. <br /> Protective Gloves: IMPERVIOUS GLOVES SHOULD BE WORN. <br /> Eye Protection: SAFETY GLASSES WITH SIDE SHIELDS OR CHEMICAL GOGGLES IF SPLASH <br /> IS POSSIBLE. <br /> Work Hygienic Practices: GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS BE <br /> FOLLOWED. <br /> ------------------------------------------------------- <br /> ------------------------------------------------------- <br /> Physical/Chemical Properties <br />