k`■ KLEINFELDER <br /> were recorded on the boring logs. No odors or discoloration were present in soil samples from <br /> soil borings B-1 and B-2. PID readings for the samples collected ranged from 4.3 to 7 ppmv. <br /> The borings were drilled, logged, and sampled in accordance with the protocol described in <br /> Attachment B. <br /> Six soil samples were collected from each of the two borings. Chemical analysis. was <br /> subsequently conducted on a total of eight soil samples, four from each boring. Groundwater was <br /> not encountered during the drilling activities. <br /> Soil cuttings and water generated while drilling were stored on site in 55 gallon drums pending <br /> chemical analysis. <br /> 4.4 SAMPLE HANDLING <br /> After collection, each of the samples were labeled, logged on a chain-of-custody, and <br /> immediately stored in an iced cooler. The samples were transported under chain-of-custody <br /> control to Kleinfelder's office and then transported by courier in a sealed container to Sequoia <br /> Analytical of Sacramento, California for chemical analysis. Sequoia is certified by the California <br /> Department of Health Services to perform the requested analyses. <br /> 20-3712-08.E02/2018R1090 Page 8 of 17 <br /> ©1998,Kleinfelder,Inc. December 23, 1998 <br />